an5418g0004b

Retrofit wiring harness for Electronic Quick Reverse (EQR)

Tyyppi an · aihe 54.18 · versio 0102 · 2012-02-15

Koskee: MODEL 405.100 /102 /120 /122 /200 /220 ## up to 201606

Ei saatavilla kielellä ”fi”; näytetään kielellä Englanti.

Sijainti

Toimintoryhmä 2 Alusta › 54 Sähkölaitteet, sähkövarusteet ja mittarit › 54.18 Johtosarjat — Mallisarja 405 (mallit 100, 102, 120, 122, 200, 220)

EinPAS 17 Voimansiirtolinja/akseli › 17.35 Vaihteensiirto/vaihdeohjaus › 17.35.3 Jälkiasennus/muutostyö — Mallisarja 405 (mallit 100, 102, 120, 122, 200, 220)

AN54.18-G-0004B

Retrofit wiring harness for Electronic Quick Reverse (EQR)

14.2.12

MODEL 405.100 /102 /120 /122 /200 /220 ## up to 201606

Retrofit wiring harness for Electronic Quick Reverse (EQR)

G54.21-3285-09

1 Cover

2 Cover

3 Cover

4 Switch panel

5 Cover

6 Center console

A7 Base module (central electrics)

Remove/install

Danger!

Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices

No fire, sparks, open flames or smoking.

Wear acid-resistant gloves and clothing and safety glasses with side guards.

Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground.

Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers.

AS54.10-Z-0001-01A

1

Disconnect battery ground line

Notes on battery

All models

AH54.10-P-0001-01A

2

Remove covers (1, 2) from electrical compartment and stowage compartment

3

Release base module (electrical center) (A7) and fold forwards

4

Remove cover (3) of switch panel (4)

5

Remove covers (5) of center console (6)

6

Remove screws for center console (6) at front and rear and tilt center console (6) to one side

7

Retrofit wiring harness for Electronic Quick Reverse (EQR) into cab

AN54.18-G-0004-01B

8

Install in the reverse order

9

Check electrical system for proper operation

Viitatut asiakirjat