AD07.53-P-6000-22A | ECM test of electrical system secondary air injection malfunction (function chain) |
| Scope of test | Tester/test connection | Operation/ Requirement | Specified value | Possible cause/ Remedy | ||
1.0 | Secondary air injection (Causal chain) Low emission engine, EURO 3/4 and vehicles with air pumps |
24 40 (1.40) |
N3/5 N3/5 |
23 60 (1.60) | Note: Measurement looks at the O2 sensor signal upstream of TWC With coolant temperature at Insert jumper at socket box |
Voltage for O2 sensor oscillates between - 0.2 V up to +1.0 V Air pump running Voltage changes to <100 mV within 20 S | Secondary air injection switchover valve (Y32) Secondary air injection relay (K17) No passage through air lines No output from air pump |