Perform SCN coding of control units for front doors and rear doors (code: 1511P54C21)

Type sm · topic 72.29 · version 0101 · 2019-11-13

Applies to: Model 222 with code Z07 (B7 armoring on special protection version)

Where it sits

Function group 3 Body › 72 Doors › 72.29 Doors - electrical system — Series 222

EinPAS 25 On-board/network/multifunction › 25.15 Network/multifunction › 25.15.11 Control unit/module/relay — Series 222

EinPAS 45 Data/information › 45.20 Information/measures › 45.20.40 Service measures — Series 222

SM72.29-P-0010A

Perform SCN coding of control units for front doors and rear doors (code: 1511P54C21)

13.11.2019

Model

222

with code Z07 (B7 armoring on special protection version)

Operation no. of the operation texts or standard texts and flat rates

Category

Op. no.

Operation text

Time

Acc. no.

Code

P

02-4762

Connect/disconnect diagnostic system (Xentry/DAS)

P

02-5058

Connect/disconnect battery charger (with Xentry/DAS connected)

P

02-9446

Perform SCN coding in control unit ......................... (with XENTRY/DAS connected)

Check

1

Check whether vehicle is affected by measure


Model 222 as of 095876 up to 158298

SM72.29-P-0010-01AAA

Programming

2

Connect diagnostic unit

Use XENTRY Diagnostics version 12/2015 with all available add-ons or a newer version. The operation steps must be performed exactly as per Xentry Diagnostics! Make sure that the vehicle's on-board electrical system battery has sufficient voltage supply (more than 12.5 V) by using a battery charger. If Xentry Diagnostics is already connected to the vehicle, continue with operation step 3.

AD00.00-P-2000-04B

3

Perform SCN coding in front door control unit at the left (N69/1)

To do so, select menu item Control units view  Seats and doors  DCU LF - left front door  Adaptations  Control unit commissioning  Commissioning of already installed control unit.

Then follow the user guidance in Xentry Diagnostics.

The SCN coding automatically starts after selecting the menu item "Commissioning of previously-installed control unit".

If two or more instances of control unit programming or SCN coding are carried out during a workshop visit, the operation items 02­4762 and 02­5058 must only be charged once for each workshop order.

4

Perform SCN coding in control unit for front door at right (N69/2)

To do so, select menu item Control units view  Seats and doors  DCU RF - right front door  Adaptations  Control unit commissioning  Commissioning of already installed control unit.

Then follow the user guidance in Xentry Diagnostics.

The SCN coding automatically starts after selecting the menu item "Commissioning of previously-installed control unit".

If two or more instances of control unit programming or SCN coding are carried out during a workshop visit, the operation items 02­4762 and 02­5058 must only be charged once for each workshop order.

5

Conduct SCN coding in control unit for rear door at left (N69/3)

To do so, select menu item Control units view  Seats and doors  DCU LR - left rear door  Adaptations  Control unit commissioning  Commissioning of already installed control unit.

Then follow the user guidance in Xentry Diagnostics.

The SCN coding automatically starts after selecting the menu item "Commissioning of previously-installed control unit".

If two or more instances of control unit programming or SCN coding are carried out during a workshop visit, the operation items 02­4762 and 02­5058 must only be charged once for each workshop order.

6

Conduct SCN coding in control unit for rear door at right (N69/4)

To do so, select menu item Control units view  Seats and doors  DCU RR - right rear door  Adaptations  Control unit commissioning  Commissioning of already installed control unit.

Then follow the user guidance in Xentry Diagnostics.

The SCN coding automatically starts after selecting the menu item "Commissioning of previously-installed control unit".

If two or more instances of control unit programming or SCN coding are carried out during a workshop visit, the operation items 02­4762 and 02­5058 must only be charged once for each workshop order.

7

Disconnect diagnostic equipment

AD00.00-P-2000-04B