W42.00-1026-09
1 Battery
2 Battery tray
4 Nut
3 Compressed air reservoir
Operation no. of operation texts or standard texts and flat rates
Category | Op. no. | Operation text | Time | Acc. no. | Code |
O | 027647 | OPERATION: RETIGHTEN TENSIONING STRAPS FOR COMPRESSED AIR RESERVOIR | 0.3 h | 42 901 89 | ANZIEH-ZET |
| Remove | ||
1 | Disconnect ground cable at battery | ||
2 | Detach electrical lines from positive and negative terminal of battery (1) | ||
3 | Remove battery (1) | ||
Retightening | |||
4 | Retighten both nuts (4) on tensioning straps of compressed air reservoir (3) | | |
| Install | ||
5 | Install battery (1) | ||
6 | Install electrical lines to positive and negative terminal of battery (1) | ||
7 | Connect ground cable to battery |
Brake lines, brake hoses
Referenced documents
- ar5410w0003a Disconnect/connect battery ground line