Operation no. of the operation texts or standard texts and flat rates | |||||
Category | Op. no. | Operation text | Time | Acc. no. | Code |
P | 02-4762 | Connect/disconnect diagnostic system (XENTRY/DAS) | |||
P | 02-5058 | Connect/disconnect battery charger (with XENTRY/DAS connected) | |||
P | 02-9334 | Update control unit ......................... software (with XENTRY/DAS connected), acc. no.: .........., code: .......... | |||
P | 02-9788 | Attach information sign for Adaptive Damping System to B-pillar | |||
1 | Information sticker |
P00.10-6154-03
| Check | ||
1 | Check whether vehicle is affected by measure |
| |
Programming | |||
2 | Connect diagnostic unit | Use XENTRY Diagnostics version 11/2016 or higher with all available addons. The operation steps must be performed exactly as per XENTRY Diagnostics! Make sure that the vehicle's on-board electrical system battery has sufficient voltage supply (more than 12.5 V) by using a battery charger. If Xentry Diagnostics is already connected to the vehicle, continue with operation step 3. | |
| |||
3 | Program adaptive damping system control unit | To do so, select menu item Control units Suspension ADS Adaptive Damping System Adaptations Control units update Update of control unit software. | |
Then follow the user guidance in Xentry Diagnostics. | |||
If two or more instances of control unit programming or SCN coding are carried out during a workshop visit, the operation items 024762 and 025058 must only be charged once for each workshop order. | |||
4 | Disconnect diagnostic equipment | ||
| |||
| Install | ||
5 | Attach information label (1) for adaptive damping system to B-pillar on driver's side |
Referenced documents
- ad0000p200004b Connect STAR DIAGNOSIS and read out fault memory
- sm3232p000401aaa Affected vehicles: Program adaptive damping system control unit and attach information label (code: 1611P32D08)