SI83.55-P-0001A | Service Information: A/C compressor | 22.10.02 |
MODEL 203 with CODE (581b) Convenience automatic air conditioning
MODEL 211 with CODE (581a) Air-conditioning (automatic)
MODEL 215
MODEL 220
MODEL 230
A/C compressor switches on frequently:
The multifunction sensor is not correctly calibrated so that incorrect values are sent to the CAN bus. This causes the A/C compressor as well as the mirror heater to switch on more frequently.
Damage code: 83 648 XX
Text in message field:"Incorrectly calibrated"
Operation no. of operation texts or standard texts and flat rates
Range | Op. no. | Operation text | Time | Acc. no. | Code |
P | 833115 | Replace multifunction sensor for activated charcoal filter (after checking), model 203 | 003 WU | --- | --- |
P | 833115 | Replace multifunction sensor for activated charcoal filter (after checking), model 215, 220 | Time prescribed by foreman | --- | --- |
P | 833115 | Replace multifunction sensor for activated charcoal filter (after checking), model 211, 230 | 002 WU | --- | --- |
| Remove and install multifunction sensor | Model 203 with CODE (581b) convenience automatic air conditioning | |
| Remove and install multifunction sensor | Models 215, 220 | |
| Remove and install multifunction sensor | Model 211.004 /006 /016 /061 /065 /070 with CODE (581b) Convenience automatic air-conditioning | |
| Remove and install multifunction sensor | Model 230.475 |
Referenced documents
- ar8340p6730m Removing and installing multifunction sensor
- ar8340p6730p Remove and install multifunction sensor
- ar8340p6730r Remove and install multifunction sensor
- ar8340p6730t Remove and install multifunction sensor