20-0020 Switching points in cooling system
Data
Models | 124 | 129 | 140 | 210 |
Thermostat at coolant temperature ° C Start of opening Max. opening |
78 - 82 94 |
78 - 82 94 |
78 - 82 94 |
78 - 82 94 |
Viscous fan coupling cut-in at airflow temperature °C Safety |
92 - 100 4500 3250 |
92 - 100 4500 3250 |
92 - 100 4500 3420 |
92 - 100 4500 3420 |
Electric auxiliary fan 2) 1st stage on/off 2nd stage on/off 3rd stage on/off |
107/100 16/11 107/100 |
100/95 - 107/100 20/15 |
100/95 14/12 107/100 4) 17/14 115/107 4) 20/17 |
95/1153) 14/203) |
A/C at coolant temperature in °C Start of cycle 5) Emergency off |
121-123 126-128 |
121-123 126-128 |
121-123 126-128 |
121-123 126-128 |
System cap opens at pressure in bar or °C max. 1st stage 2nd stage |
1.3 - 1.5 130 - 134 - |
1.3 - 1.5 130 - 134 1.8 - 2.2 137 - 143 |
1.3 - 1.5 6) 130 - 134 6) - |
1.3 - 1.5 130 - 134 1.8 - 2.2 137 - 143 |
2) At coolant temperature in °C or refrigerant pressure in bar, 1st stage cuts in in line with vehicle speed: compressor
switched on
<40 km/h on
>70km/h off
3) Fully engaged
4) USA circuit. A/C off (EC button pressed), outside air>15°C. 2nd stage of this version operates at 107/100°C or 17/14 bar, respectively
5) Cycle: 50% ON period, 20 seconds on
20 seconds off
6) From outside temperature of >10°C
Referenced documents
- ra01001190010x 0010 - Engine and model survey Engine 119.96 KE, 119.97 LH 119.98 ME