07.2-169 Testing leaktightness of 2nd stage aneroid cell
Operation no. of operation texts and work units or standard texts and flat rates 07-1203 or 07-1206 |
0107-32284
Vacuum hose (27) | detach, fit on. |
Hand vacuum pump (001 589 73 21 00) to vacuum port of aneroid cell (3) |
attach, detach. Build up vacuum. Vacuum must not drop. Replace aneroid cell (3) if necessary. |
Special tool
Referenced documents
- ra07001020001x 0001 - Model designations, installation overview, distinguishing feature KAT/RÜF Engine 102 - 2 E-E Carburetor
- ra07001020114x 0114 - Testing routine: Engine 102 - 2 E-E Carburetor A. Component arrangement, B. Test equipment, C. Test connection diagram, D. Contact assignment, E. Conditions/test instr. F.-K. Readouts/wiring diagrams
- ra0700102pr4ax Programmed repairs: Carburetor system Engine 102 - 2 E-E Carburetor
- ra0700102ta00x Technical modifications: Carburetor system Engine 102 - 2 E-E Carburetor