GF86.10-P-2000MB | Automatic triggering, function | 19.10.11 |
MODEL 220.175 /178
with CODE (Z04) Light armoring
with CODE (Z07) Top protection
with fire extinguishing system
The fire extinguishing system is triggered automatically, if one of the two engine fire extinguishing system temperature sensors (B65) or rear fire extinguishing system temperature sensor (B65/1) is greater than 160 °C.
Function sequence
The engine fire extinguishing system temperature sensors (B65) or rear fire extinguishing system temperature sensor (B65/1) relays a ground signal to the fire extinguishing system control unit (N100). The control unit outputs an ignition pulse to the extinguishing agent tank squibs 1 and 2 (R42 and R42/1).
The extinguishing agent tank lock is enabled, the extinguishing agent flows into the pipe system and the exits at the holes and nozzles.
Simultaneously the extinguishing agent warning buzzer (H13) is actuated.
Referenced documents
- gf8610p2100mb Temperature sensor location/task
- gf8610p2101mb Fire extinguishing agent canister location and design
- gf8610p2103mb Warning buzzer location/task
- gf8610p2104mb Fire extinguishing system control module location/task