gf8610p2000mb

Automatic triggering, function

Type gf · topic 86.10 · version 0102 · 2011-10-26

Applies to: MODEL 220.175 /178 with CODE (Z04) Light armoring with CODE (Z07) Top protection with fire extinguishing system

Where it sits

Function group 3 Body › 86 Emergency equipment, diability equipment, sanitary equipment, galley › 86.10 Emergency equipment — Series 220 (models 175, 178)

GF86.10-P-2000MB

Automatic triggering, function

19.10.11

MODEL 220.175 /178
with CODE (Z04) Light armoring
with CODE (Z07) Top protection
with fire extinguishing system

The fire extinguishing system is triggered automatically, if one of the two engine fire extinguishing system temperature sensors (B65) or rear fire extinguishing system temperature sensor (B65/1) is greater than 160 °C.

Function sequence

The engine fire extinguishing system temperature sensors (B65) or rear fire extinguishing system temperature sensor (B65/1) relays a ground signal to the fire extinguishing system control unit (N100). The control unit outputs an ignition pulse to the extinguishing agent tank squibs 1 and 2 (R42 and R42/1).

The extinguishing agent tank lock is enabled, the extinguishing agent flows into the pipe system and the exits at the holes and nozzles.

Simultaneously the extinguishing agent warning buzzer (H13) is actuated.

Temperature sensor, location/task

GF86.10-P-2100MB

Fire extinguishing system control unit, location/task

GF86.10-P-2104MB

Warning buzzer, location/task

GF86.10-P-2103MB

Extinguishing agent tank, location/task

GF86.10-P-2101MB

Referenced documents