GF83.70-W-2002D | Stop heating function | 27.1.98 |
MODELS 950, 952, 953, 954
with CODE (H60) Warm air heater "Eberspächer D1 LP"
with CODE (H62) Warm air heater "Eberspächer D3 LP"
MODELS 970, 972, 974, 975, 976
with CODE (H60) Warm air auxiliary heater "Eberspächer" D1 LP
with CODE (H62) Warm air auxiliary heater "Eberspächer" D3 LP
MODELS 375.4, 944 with CODE (H60) Warm air heater "Eberspächer D1 LP"
W83.70-0142-09
1 Fuses
2 Warm air blower
3 Controller board with temperature sensor
4 Combustion air and heater blower
5 Combustion air blower
6 Glow plug
13 Fuel metering pump
14 Timer
A Fuel supply line
B Combustion air inlet
C Exhaust outlet
D Cold air inlet
E Warm air outlet
7 Overheating sensor
8 Burner insert
9 Flame sensor
10 Afterburner pipe
11 Heat exchanger
12 Jacket
"Switch off from partial load or full power" function procedure
The heater is heating at partial load or full power.
Heating is stopped by manually switching off at the
timer (14).
The heater goes into power-down mode:
- Fuel delivery is stopped immediately by switching off the fuel metering pump (13).
- The combustion air and heater blowers (5, 2) continue running for a certain time run in order to cool the heater.
In order to remove combustion residue the glow plug (6) remains on for approx. 15 seconds during power-down.
When the power-down mode is finished, all heater components are switched off.
"Switching off during control interval" function procedure
If no fuel has been delivered yet or the heater is in a control interval, the heater is switched off immediately - no power-down takes place.
Heat exchanger location/task/design | |||
Glow plug location/task | |||
Flame sensor location/task | |||
Timer location/task/design | |||
Fuel metering pump location/task/design | |||
Overheating sensor location/task/design | |||
Combustion air and heater blower location/task/design | |||
Auxiliary heater controller board location/task/design | |||
Burner insert with afterburner pipe location/task/design |
Referenced documents
- gf8370w4013a Glow plug, location/task
- gf8370w4014a Flame sensor, location/task
- gf8370w4017d Heat exchanger, location/task/design
- gf8370w4022c Timer, location/task/design
- gf8370w4023a Fuel metering pump, location/task/design
- gf8370w4025b Overheating sensor, location/task/design
- gf8370w4027c Combustion/warm air fan location/task/design
- gf8370w4028c Auxiliary heater control board, location/task/design
- gf8370w4029c Burner insert with afterburner pipe, location/task/design