Where it sits

Function group 3 Body › 83 Climate control › 83.70 Auxiliary/supplementary heater — Series 375 (models 4**) · Series 944 · Series 970 · Series 972 · Series 974 · Series 975 · Series 976

GF83.70-W-2002C

End heater operation, function

17.10.97

MODELS 970, 972, 974, 975, 976 with CODE (H61) Webasto Air Top 2000 hot air auxiliary heater

MODELS 375.4, 944 with CODE (H61) "Webasto" Air Top 2000 hot air auxiliary heater

End heater operation, function

W83.70-0109-06

1 Heater unit

2 Heating air inflow vents

3 Combustion and heated air blower

4 Control IC

5 Flame sensor

6 Glow pin

7 Burner insert

8 Temperature limiter

9 Afterburner pipe

10 Heat exchanger

11 Fuel metering pump

12 Timer

13 Rotary potentiometer

A Exhaust

HA Heater outlet

HE Heater inlet

V Combustion air

Terminate heating mode from partial or full load

Requirements

The heater's (1) heating mode is switched on at the timer (12).

The heater (1) is in the full load or partial load range.

Terminate heater operation

Heater operation is terminated:

by switching it off manually on the timer (12), or

because of an automatic shut down initiated to prevent impermissibly high operating temperatures (> 140 °C). In doing so the temperature limiter (8) records the excess temperature and issues a signal to the controller board (4).

In both instances the controller board (4) interrupts the fuel metering pump's circuit (11) and the heater (1) switches into power-down:

- The combustion and heated air blower (3) continues to run for 35 seconds at 60 % of the maximum speed. This serves to cool the combustion chamber and purge it of combustion gases.

- As soon as the flame monitor (5) detects "Flame out", the combustion and heated air blower speed are increased to maximum speed for 60 seconds.

- After this during the ensuing 60 seconds the speed of the combustion and heated air blower (3) is reduced in stages to "zero".

Once the power-down phase is over all heater (1) components are switched off.

Terminate heater operation from the control interval mode

Prerequisites

No fuel is being delivered, or

the heater (1) is in the control interval mode.

Terminate heater operation

The heater (1) is switched off immediately without starting the power-down mode.

Heat exchanger, location/task/design

GF83.70-W-4017C

Heating element, location/task/design

GF83.70-W-4020C

Flame monitor, location/task/design

GF83.70-W-4021C

Timer, location/task/design

GF83.70-W-4022C

Fuel metering pump, location/task/design

GF83.70-W-4023B

Temperature limiter, location/task/design

GF83.70-W-4026B

Combustion and heated air blower, location/task/design

GF83.70-W-4027B

Controller board, location/task/design

GF83.70-W-4028B

Burner insert with afterburner pipe, location/task/design

GF83.70-W-4029B

Referenced documents