GF83.70-W-2002C | End heater operation, function | 17.10.97 |
MODELS 970, 972, 974, 975, 976 with CODE (H61) Webasto Air Top 2000 hot air auxiliary heater
MODELS 375.4, 944 with CODE (H61) "Webasto" Air Top 2000 hot air auxiliary heater
W83.70-0109-06
1 Heater unit
2 Heating air inflow vents
3 Combustion and heated air blower
4 Control IC
5 Flame sensor
6 Glow pin
7 Burner insert
8 Temperature limiter
9 Afterburner pipe
10 Heat exchanger
11 Fuel metering pump
12 Timer
13 Rotary potentiometer
A Exhaust
HA Heater outlet
HE Heater inlet
V Combustion air
Terminate heating mode from partial or full load
Requirements
The heater's (1) heating mode is switched on at the timer (12).
The heater (1) is in the full load or partial load range.
Terminate heater operation
Heater operation is terminated:
by switching it off manually on the timer (12), or
because of an automatic shut down initiated to prevent impermissibly high operating temperatures (> 140 °C). In doing so the temperature limiter (8) records the excess temperature and issues a signal to the controller board (4).
In both instances the controller board (4) interrupts the fuel metering pump's circuit (11) and the heater (1) switches into power-down:
- The combustion and heated air blower (3) continues to run for 35 seconds at 60 % of the maximum speed. This serves to cool the combustion chamber and purge it of combustion gases.
- As soon as the flame monitor (5) detects "Flame out", the combustion and heated air blower speed are increased to maximum speed for 60 seconds.
- After this during the ensuing 60 seconds the speed of the combustion and heated air blower (3) is reduced in stages to "zero".
Once the power-down phase is over all heater (1) components are switched off.
Terminate heater operation from the control interval mode
Prerequisites
No fuel is being delivered, or
the heater (1) is in the control interval mode.
Terminate heater operation
The heater (1) is switched off immediately without starting the power-down mode.
Heat exchanger, location/task/design | |||
Heating element, location/task/design | |||
Flame monitor, location/task/design | |||
Timer, location/task/design | |||
Fuel metering pump, location/task/design | |||
Temperature limiter, location/task/design | |||
Combustion and heated air blower, location/task/design | |||
Controller board, location/task/design | |||
Burner insert with afterburner pipe, location/task/design |
Referenced documents
- gf8370w4017c Heat exchanger, location/task/design
- gf8370w4020c Heating element, location/task/design
- gf8370w4021c Flame monitor, location/task/design
- gf8370w4022c Timer, location/task/design
- gf8370w4023b Fuel metering pump, location/task/design
- gf8370w4026b Temperature limiter, location/task/design
- gf8370w4027b Combustion air/heated air blower, location/task/design
- gf8370w4028b Controller board for auxiliary heater, location/task/design
- gf8370w4029b Burner insert with afterburner pipe, location/task/design