Terminate heater mode, function

Type gf · topic 83.70 · version 0102 · 2005-09-21

Applies to: MODEL 639.711 /713 with CODE (HZ1) Warm air auxiliary heater (Westfalia)

Where it sits

Function group 3 Body › 83 Climate control › 83.70 Auxiliary/supplementary heater — Series 639 (models 711, 713)

GF83.70-S-2002S

Terminate heater mode, function

20.12.03

MODEL 639.711 /713 with CODE (HZ1) Warm air auxiliary heater (Westfalia)

Terminate heater mode, function

N83.70-2204-11

26 "Weekday" display

27 "°C" display

28 "Stationary heating mode" display

29 "Time, switch-on time and outside temperature" multiple display

30 "Activated switch-on times" display

31 Display field

32 Heat output control knob

33 "Increase" button

34 "Decrease" button

35 "ON/OFF" button for auxiliary heater

36 "Switch-on time, weekday and timer" button

37 "Time and preset time" button

N35 STH warm air timer

The heating mode is switched off directly on the STH warm air timer (N35) or the heater unit (A7) or by preselectionFuel delivery is stopped immediately by shutting off the warm air STH fuel metering pump (M46/2). To cool down the heater unit (A7) the hot air blower fan motor (A7m1) is activated for approx.
t = 4 min. (cold blow phase). The glow pin (A7r1) is actuated for
t = 40 s during the cold blow phase to clean it from possible combustion residuesWhen the cold blow phase is completed, all heater unit (A7) components are switched off

Deactivate heater mode from the standby mode

If fuel is not supplied until the heater unit (A7) is deactivated or the heater unit (A7) is in the stage "OFF", the heater unit (A7) is switched off immediately without activating the hot air blower fan motor (A7m1) (cold blow phase).

-----------------------------------------------------------------------------------------

Manual mode without timer

Deactivate heater unit (A7)

The ON/OFF button for the auxiliary heater (35) must be pressed. Deactivation is indicated in the display field (31) of the STH warm air timer (N35) by extinguishing the "Stationary heater mode" display (28).

Program timer

Erase switch-on time

Press the "Switch-on time, weekday and timer" (36) button until the number in the "Activated switch-on times" display (30) in the display field (31) of the STH warm air timer (N35) is erased.

Only the currently displayed switch-on time can be erased.

-----------------------------------------------------------------------------------------

Heater unit (A7) switch-off malfunction

A shutoff takes place if one of the following conditions exists:

In case of undervoltage (U < 10.5 V) or overvoltage
(U > 16 V), the heater unit (A7) is switched off after 20 s

When the overheating and flame sensor unit (A7r3) is defective or the electrical line to the overheating and flame sensor unit (A7r3) is interrupted, the heater unit (A7) is started and only switched off during the startup phase

If the hot air blower fan motor (A7m1) does not start or if the speed deviates min. 10 %, the heater unit (A7) is switched off after = 30 s

After a malfunction switch-off, the actuation of the warm air STH fuel metering pump (M46/2) is interrupted and the hot air blower fan motor (A7m1) continues to run for
t = 4 min.

Glow pin, location/task

GF83.70-S-4005S

Heat exchanger, location/task/design

GF83.70-S-4017S

Fuel metering pump, location/task/design

GF83.70-S-4023SA

Combustion air/hot air blower, location/task/design

GF83.70-S-4027S

Burner insert with burner tube, location/task/design

GF83.70-S-4029S

Auxiliary heating control unit (ZHE), location/task

GF83.70-S-4105S

Auxiliary heater (ZHE) switch clock, location/task/design

GF83.70-S-4120S

Overheating and flame sensor, location/task

GF83.70-S-4125S

Auxiliary heater unit (ZHE), location/task/design

GF83.70-S-4130S

Referenced documents