gf8370d2011h

Stationary heater (STH) operating time, function

Type gf · topic 83.70 · version 0100 · 2008-11-26

Applies to: MODEL 906.111 /113 /131 /133 /135 /153 /155 /211 /213 /231 /233 /235 /253 /255 /611 /613 /631 /633 /635 /637 /653 /655 /657 /711 /713 /731 /733 /735 as of 1.9.08 with CODE (H12) Auxiliary heater (warm water) with CODE (HY1) Radio remote control for auxiliary heater MODEL 906.611 /613 /631 /633 /635 /637 /653 /655 /657 /711 /713 /731 /733 /735 as of 1.9.08 with CODE (HZ5) 10kW warm water auxiliary heater with timer with CODE (HY1) Radio remote control for auxiliary heater

Where it sits

Function group 3 Body › 83 Climate control › 83.70 Auxiliary/supplementary heater — Series 906 (models 111, 113, 131, 133, 135, 153, 155, 211, 213, 231, 233, 235, 253, 255, 611, 613, 631, 633, 635, 637, 653, 655, 657, 711, 713, 731, 733, 735)

GF83.70-D-2011H

Stationary heater (STH) operating time, function

18.11.08

MODEL 906.111 /113 /131 /133 /135 /153 /155 /211 /213 /231 /233 /235 /253 /255 /611 /613 /631 /633 /635 /637 /653 /655 /657 /711 /713 /731 /733 /735 as of 1.9.08
with CODE (H12) Auxiliary heater (warm water)
with CODE (HY1) Radio remote control for auxiliary heater

MODEL 906.611 /613 /631 /633 /635 /637 /653 /655 /657 /711 /713 /731 /733 /735 as of 1.9.08
with CODE (HZ5) 10kW warm water auxiliary heater with timer
with CODE (HY1) Radio remote control for auxiliary heater

Change operating time via the stationary heater (STH) radio remote control (RRC [FFB]) for auxiliary heater

With the RRC [FFB] switched on and the red light-emitting diode (LED) flashing on the STH RRC [FFB], press the activate button and the OK button simultaneously. The LED on the STH RRC [FFB] illuminates in green. Now press the activate button repeatedly until the required operating time is displayed.

The following intervals can be set:

20 min: the LED of the STH RRC [FFB] flashes twice in green.

30 min: the LED of the STH RRC [FFB] flashes three times in green.

40 min: the LED of the STH RRC [FFB] flashes four times in green.

60 min: the LED of the STH RRC [FFB] flashes six times in green.

Once the operating time has been selected, the

OK button must be pressed. The LED illuminates in red for the duration of the data transfer. If the LED performs 2 long green flashes, the selected operating time has been saved. If no settings have been made, the LED flashes 6 times and the STH RRC [FFB] goes into the idle state.

STH control unit, component description

GF83.70-D-4200H

STH radio remote control receiver, component description

GF83.70-D-4201HF

STH radio remote control transmitter, component description

GF83.70-D-4204HF

STH or HB switch, component description

GF83.70-D-4206H

Referenced documents