gf8370d2001a

Heater operation, function

Type gf · topic 83.70 · version 0101 · 1998-07-08

Applies to: MODEL 902.32 /42, 903.32 /42, 904.32 /42 with CODE (H11) Hot air auxiliary heater Heater designation D1L-C MODEL 903.02 with CODE (H11) Hot air auxiliary heater Heater designation B1L-C

Where it sits

Function group 3 Body › 83 Climate control › 83.70 Auxiliary/supplementary heater — Series 902 (models 32*, 42*) · Series 903 (models 02*, 32*, 42*) · Series 904 (models 32*, 42*)

GF83.70-D-2001A

Heater operation, function

1.10.96

MODEL 902.32 /42, 903.32 /42, 904.32 /42 with CODE (H11) Hot air auxiliary heater
Heater designation D1L-C

MODEL 903.02 with CODE (H11) Hot air auxiliary heater
Heater designation B1L-C

Heater operation, function

D83.70-0052-05

1 Fresh air fan impeller
2 Circuit board
3 Combustion air blower impeller
4 Glow plug
5 Overheat switch
6 Combustion chamber
7 Flame sensor
8 Heat exchanger
9 Outer jacket
10 Flange gasket
11 Blower motor

The fuel metering pump starts pumping a precisely metered quantity of fuel into the combustion chamber after a preglowing time of approx. 40 seconds.

The fuel forms a mixture capable of combustion in combination with the combustion air which is ignited by the glow plug.

The flame is monitored by the flame sensor.

The maximum permissible temperature is monitored by an overheat switch.

The combustion gases flow through the heat exchanger. The glow plug is switched off.

The heater is now in operation.

The control module regulates the entire operating sequence in the heating mode in combination with the circuit board.

The flame sensor and overheat switch have an effect on the control module for switching off the heater in the event of a malfunction.

Fuel metering pump, location/purpose

GF83.70-D-4008A

Glow plug, location/purpose

GF83.70-D-4013A

Flame sensor, location/purpose

GF83.70-D-4014A

Auxiliary heater control module, location/purpose

GF83.70-D-4015A

Circuit board, location/purpose

GF83.70-D-4016A

Referenced documents