gf8340p2001e

Refrigerant circuit, function

Type gf · topic 83.40 · version 0101 · 1998-09-10

Applies to: MODEL 202 with CODE (580) Air conditioning or, for USA, Tempmatic A/C with CODE (581a) Air conditioning (automatic)

Where it sits

Function group 3 Body › 83 Climate control › 83.40 Air conditioning (automatic) — Series 202

GF83.40-P-2001E

Refrigerant circuit, function

23.1.98

MODEL 202
with CODE (580) Air conditioning or, for USA, Tempmatic A/C
with CODE (581a) Air conditioning (automatic)

Refrigerant circuit, function

S83.30-2034-12

1 A/C compressor
2 Condenser
3 Receiver/drier
4 Expansion valve
5 Evaporator

A High pressure (gaseous)
B High pressure (liquid)
C Low pressure (liquid)
D Low pressure (gaseous)

The A/C compressor (1) is driven by the engine and compresses the gaseous refrigerant which heats up and then flows into the condenser (2).
The heat from compression is absorbed from the refrigerant by the surface of the condenser (2). The refrigerant liquefies as it cools.
Chemical and other impurities are removed as the refrigerant flows through the receiver drier (3).
The expansion valve (4) sprays the cooled, liquid refrigerant into the evaporator (5) located in the fresh air flow and the refrigerant evaporates. This evaporation process absorbs heat from the fresh air flowing through the system of tubes and honeycombs, cooling the air.

The entrained moisture in the air is condensed out and drained to the outside. The air is dried. The A/C compressor (1) sucks in the refrigerant, which has become gaseous from absorbing heat, and compresses it again.

When the engine is running and the blower switched on, cooled air can be routed into the passenger compartment through various outlet openings. The cooling intensity depends on the passenger compartment temperature setting and the blower output.

Auxiliary fan, location/purpose/function

Engine 111 up to 31.05.96

Engines 111.944/975 as of 01.06.96

Engines 104, 112, 601, 604, 605

GF83.40-P-2162E

Auxiliary fan control module, location/purpose/function

Engines 104, 112, 601, 604, 605 as of 01.09.95

Engine 111 as of 01.09.95 up to 31.05.96

Engines 111.944/975 as of 01.06.96

GF83.40-P-2163E

Auxiliary fan preresistor, location/purpose/function

up to 31.08.95

GF83.30-P-2114E

Auxiliary fan relay, location/purpose/function

up to 31.08.95

GF83.30-P-2115E

Engine/A/C electric fan, location/purpose/function

Engine 111 except 111.944/975 as of 01.06.96

Engine 611

GF83.40-P-2151E

Engine/A/C electric fan control module, location/purpose/function

Engine 111 except 111.944/975 as of 01.06.96

Engine 611

GF83.40-P-2167E

Condenser, location/purpose/function

GF83.40-P-2152A

Evaporator, location/purpose/function

GF83.40-P-2164A

Receiver/drier (Tempmatic), location/purpose/function

only with code 580

GF83.30-P-2120A

Receiver/drier, location/purpose/function

only with code 581a

GF83.40-P-2153A

Expansion valve, location/purpose/design/function

GF83.40-P-2123A

Refrigerant temperature sensor, location/purpose/function

only with code 581a

GF83.40-P-2154A

Coolant temperature sensor
air conditioning, location/purpose/function

GF83.40-P-2155A

Refrigerant pressure sensor, location/purpose/function

GF83.40-P-2156A

A/C compressor, location/purpose/design/function

up to 31.08.95

GF83.55-P-2100E

as of 01.09.95

GF83.55-P-2100A

Electro-magnetic clutch, location/purpose/design/function

GF83.55-P-2101A

A/C compressor speed sensor, location/purpose/function

Model 202 up to 08/95 with engines 104, 111, 601, 604 and 605

GF83.55-P-2105E

A/C compressor microswitch, location/purpose/function

Model 202 up to 08/95 with engines 601, 604 and 605

GF83.55-P-2106E

Evaporator temperature sensor, location/purpose/function

GF83.57-P-2109A

Referenced documents