gf8340p2001a

Refrigerant circuit, function

Type gf · topic 83.40 · version 0103 · 1999-05-31

Applies to: MODEL 210 with CODE (580) Air conditioning or, for USA, Tempmatic A/C with CODE (581a) Air conditioning (automatic) with CODE (498) Japanese version

Where it sits

Function group 3 Body › 83 Climate control › 83.40 Air conditioning (automatic) — Series 210

GF83.40-P-2001A

Refrigerant circuit, function

3.6.97

MODEL 210
with CODE (580) Air conditioning or, for USA, Tempmatic A/C
with CODE (581a) Air conditioning (automatic)
with CODE (498) Japanese version

Refrigerant circuit, function

S83.30-2034-12

1 A/C compressor
2 Condenser
3 Receiver/drier
4 Expansion valve
5 Evaporator

A High pressure (gaseous)
B High pressure (liquid)
C Low pressure (liquid)
D Low pressure (gaseous)

The A/C compressor (1) is driven by the engine and compresses the gaseous refrigerant, which is heated during this process and flows to the condenser (2).
The heat in the refrigerant resulting from compression is absorbed by the surface of the condenser (2). The refrigerant liquefies as it cools.
As it flows through the receiver/drier (3) the refrigerant is purified of any chemical or mechanical impurities.
The expansion valve (4) sprays the cooled liquid refrigerant into the evaporator (5), which is located in the stream of fresh air. Here the refrigerant evaporates. This evaporation process absorbs heat from the fresh air flowing by on the outside through the tube and honeycomb system cooling the air.

The moisture entrained in the air condenses and is drained outside. The air is dried. The A/C compressor (1) sucks in the refrigerant which has become gaseous due to the heat absorbed and compresses it again.

Cooled air can be routed to various outlet openings in the passenger compartment with the engine running and blower switched on. The intensity of the cooling depends on the temperature set for the passenger compartment and the blower power.

Zusatzlüfter, location/purpose/function

Engines 104/119/602/604/605 and 606

Engine 111 up to 08.96

Engine 113 as of 03.97

Engine 112 up to 05.98
Engine 613 as of 07.99

GF83.40-P-2162A

Cycle module, location/purpose/function

Engine 119

Engines 104/111/602/604/605/606
up to 08.96

GF83.40-P-2166A

Auxiliary fan control module, location/purpose/function

Engine 104 from 09/96 to 02/97
Engines 602/604/605 and 606 as of 09/96

Engine 113 as of 03.97

Engine 112 up to 05.98
Engine 613 as of 07.99

GF83.40-P-2163A

Electric fan engine/AC, location/purpose/function

Engine 111 except 111.947 as of 09.96

Engine 111.947 as of 03.97

Engine 611 as of 03.97

Engine 112 as of 06.98

GF83.40-P-2151A

Electric fan engine/AC control module, location/purpose/function

Engine 111 except 111.947 as of 09.96

Engine 111.947 as of 03.97

Engine 611 as of 03.97

Engine 112 as of 06.98

GF83.40-P-2167A

Condenser, location/purpose/function

GF83.40-P-2152A

Evaporator, location/purpose/function

GF83.40-P-2164A

Receiver/drier (Tempmatic), location/purpose/function

Only with code 580

GF83.30-P-2120A

Receiver/drier, location/purpose/function

Only with codes 581a and 498

GF83.40-P-2153A

Expansion valve, location/purpose/design/function

GF83.40-P-2123A

Refrigerant temperature sensor, location/purpose/function

Only with codes 581a and 498

GF83.40-P-2154A

Air conditioning coolant temperature sensor, location/purpose/function

GF83.40-P-2155A

Refrigerant pressure sensor, location/purpose/function

GF83.40-P-2156A

A/C compressor, location/purpose/design/function

GF83.55-P-2100A

Electro-magnetic clutch, location/purpose/design/function

GF83.55-P-2101A

Evaporator temperature sensor, location/purpose/function

GF83.57-P-2109A