GF83.40-L-2001VA | Refrigerant circuit function | 21.12.00 |
MODEL 414.700 with CODE (H06) Air conditioning
S83.30-2034-12
1 Refrigerant compressor
2 Capacitor
3 Receiver with drier
4 Expansion valve
5 Evaporator
A High pressure (gaseous)
B High pressure (liquid)
C Low pressure (liquid)
D Low pressure (gaseous)
The refrigerant compressor (1) driven by the motor compresses the gaseous refrigerant, which is thereby heated up and routed to the condenser (2).
The refrigerant's compression heat is then withdrawn on the surface of the condenser (2). While cooling down, the refrigerant liquefies.
When the refrigerant flows through the fluid reservoir (3) it is cleansed of any chemical and mechanical impurities .
The expansion valve (4) sprays the cooled and liquefied refrigerant into the evaporator core (5), which is located in the fresh-air flow. The refrigerant is then vaporized. Through the vaporization process, the fresh air from outside, which flows past the pipe and honeycomb system, dissipates heat so that it cools down.
The air humidity carried along is converted to condensed water, which escapes into the open. The air dries out.
The refrigerant compressor (1) aspirates the refrigerant which has turned gaseous on account of the heat absorption and then compresses it yet again.
When the engine is running and the blower switched on, the interior can be supplied with cooled air through the various air outlets. Cooling intensity is dependent upon the preset in-car temperature and blower setting.
Condenser position/task/function | |||
Evaporator, location/purpose/design/function | |||
Air conditioning fluid reservoir, location/task/function | |||
Expansion valve, location/task/design/function | |||
Refrigerant pressure sensor, location/task/function | |||
Refrigerant compressor, location/task/design/function | |||
Control valve, location/task/function | |||
Belt pulley, location/task/design/function | |||
Pressure relief valve, location / task / function |
Referenced documents
- gf8330l2120va Air conditioning fluid reservoir, location/task/function
- gf8340l2121va Evaporator, location/purpose/design/function
- gf8340l2123va Expansion valve, location/purpose/design/function
- gf8340l2152va Condenser position/task/function
- gf8340l2156va Refrigerant pressure sensor, location/purpose/function
- gf8355l2100va Refrigerant compressor, location/task/design/function
- gf8355l2102va Control valve, location/purpose/function
- gf8355l2103va Belt pulley, location/task/design/function
- gf8355l2104va Pressure relief valve, location/task/function