GF83.25-P-2000C | Automatic heater pushbutton control module position/function | 11.12.97 |
MODEL 202 up to 31.8.95
with CODE (305a) Dust filter
with CODE (450) Taxi version
P83.25-2007-11
1 Temperature selection wheels
2 Blower switch
3 Air distribution switch
Recirculated air pushbutton
N18/3 Automatic heater (HEAT) with ventilation, control and operating module
Function
The control and operating module (N18/3) is the centerpiece of the automatic heater (HEAT). It permits performance, of adjustments required by the driver, such as:
Temperature by using the temperature selection wheels (1)
Air quantity by using the blower switch (2)
Air distribution by using the air distribution switch (3)
Recirculated air by pressing the recirculated air pushbutton
( )
Furthermore the control module integrated into the control and operation module (N18/3) takes over the comparison of specified / actual temperature values and adjustment of the preselected passenger compartment temperature.
The control and operation module (N18/3) can be diagnosed so that faults arising are stored in a fault memory, which can be read out with the aid of the DMNL Air conditioning system
Referenced documents
- gf8325p2103a Air distribution switch, location/purpose/function
- gf8325p2104a Blower switch, location/purpose/function
- gf8325p2105a Temperature selector, location/purpose/function
- gf8340p2145a Recirculating air pushbutton, position/task/function