gf8310p2001f

Vacuum system, function

Type gf · topic 83.10 · version 0101 · 1998-09-10

Applies to: MODEL 208 with CODE (581a) Air conditioning (automatic)

Where it sits

Function group 3 Body › 83 Climate control › 83.10 Ventilation — Series 208

GF83.10-P-2001F

Vacuum system, function

15.12.97

MODEL 208 with CODE (581a) Air conditioning (automatic)

Vacuum system, function

P83.40-0408-06

35 Cockpit separation point

37 Left defroster nozzle flap vacuum element

38 Right defroster nozzle flap vacuum element

41 Vacuum element for center nozzle diverter flap

42 Vacuum element for right center nozzle blend flap

43 Vacuum element for left center nozzle blend flap

44 Vacuum element for fresh air/recirculated air flap

47 Left footwell flap vacuum element

48 Right footwell flap vacuum element

Y 11 Switchover valve block

Function

All flaps (37, 38, 41, 42, 43, 44, 47 and 48) serving for the air distribution are actuated by the vacuum system.
Vacuum is connected to the switchover valve block (Y11) via the cockpit separation point (35). Depending on the settings on the pushbutton control module (N22) the individual flaps
(37, 38, 41, 42, 43, 44, 47 and 48) are released for control by the switchover valve block (Y11).

Switchover valve block, location/purpose/function

GF83.10-P-2153A

Defroster nozzle vacuum element, location/purpose/design/function

GF83.10-P-2116A

Blend flap vacuum element, location/purpose/design/function

GF83.10-P-2118A

Footwell flap vacuum element, location/purpose/design/function

GF83.10-P-2120A

Vacuum element for fresh air/recirculated air flap, location/purpose/function

GF83.10-P-2159A

Diverter flap vacuum element, location/purpose/design/function

GF83.10-P-2123A

Referenced documents