HVAC |
Item | Description |
Air mass flow rate | 14 kg/min |
Cooling | |
Refrigerant | R134a (Tetrafluroethane - CF3CH2F) |
cooling capacity | 1.2 kg |
Refrigerant temperature | -40°C to +135°C |
Air Conditioning | |
AC performance | The internal cab temperature must be down from 40°C to 25°C within 10 minutes |
General operating temperature | -40°C to 90°C (ambient) |
Windshield defrost | 10 minutes after test start 80% of area A acc. EU 78/317 (AIS 084 when implemented) must be defrosted. |
20 minutes after test start 95% of area B acc. EU 78/317 (AIS 084 when implemented) must be defrosted | |
Windshield demist | 5 minutes after test start 90% of area A acc. EU 78/317 (AIS 084 when implemented) must be dried. |
5 minutes after test start 90% of area B acc. EU 78/317 (AIS 084 when implemented) must be dried. | |
HVAC Controls | AC On/Off Switch |
Temperature Control Knob | |
Mode Control Knob | |
Blower Speed Control Knob | |
AC Vent | |