gf8300y0800a

Climate control as-built configuration

Type gf · topic 83.00 · version 0103 · 2019-10-09

Applies to: Model 400.262/281/543/571/594/597

Where it sits

Function group 3 Body › 83 Climate control › 83.00 General — Series 400 (models 262, 281, 543, 571, 594, 597)

EinPAS 39 Heating/ventilation/cooling › 39.15 Climate control › 39.15.1 Basic information — Series 400 (models 262, 281, 543, 571, 594, 597)

GF83.00-Y-0800A

Climate control as-built configuration

09.10.2019

Model

400.262/281/543/571/594/597

HVAC

Item

Description

Air mass flow rate

14 kg/min

Cooling

Refrigerant

R134a (Tetrafluroethane - CF3CH2F)

cooling capacity

1.2 kg

Refrigerant temperature

-40°C to +135°C

Air Conditioning

AC performance

The internal cab temperature must be down from 40°C to 25°C within 10 minutes

General operating temperature

-40°C to 90°C (ambient)

Windshield defrost

10 minutes after test start 80% of area A acc. EU 78/317 (AIS 084 when implemented) must be defrosted.

20 minutes after test start 95% of area B acc. EU 78/317 (AIS 084 when implemented) must be defrosted

Windshield demist

5 minutes after test start 90% of area A acc. EU 78/317 (AIS 084 when implemented) must be dried.

5 minutes after test start 90% of area B acc. EU 78/317 (AIS 084 when implemented) must be dried.

HVAC Controls

AC On/Off Switch

Temperature Control Knob

Mode Control Knob

Blower Speed Control Knob

AC Vent