TELE AID switch-on/switch-off characteristics, function

Type gf · topic 82.95 · version 0101 · 2006-02-28

Applies to: MODEL 211.0 /2 with CODE (359) TELE AID emergency call system with CODE (491) USA version

Where it sits

Function group 3 Body › 82 Electrical system, body › 82.95 Emergency call system — Series 211 (models 0**, 2**)

GF82.95-P-2000TM

TELE AID switch-on/switch-off characteristics, function

20.2.04

MODEL 211.0 /2
with CODE (359) TELE AID emergency call system
with CODE (491) USA version

Function requirements

Each telematics service must be authorized separately. If a malfunction occurs or no authorization takes place, an error message is displayed on the multifunction display (A1p13) of the instrument cluster (A1) and on the display of the COMAND operating, display and control unit (A40/3). The system is ready for operation when circuit 30 is active.

Self-test

If circuit 15R is active, the emergency call system control unit (N123/4) performs a self-test (approx. t = 3.5 sec.). If the test is successful the system is ready for operation.

Emergency call termination

Deactivation is normally carried out by the emergency call center.

The emergency call set-up is aborted after the emergency call system control unit (N123/4) has attempted to dial in
5 times without success.

TELE AID control unit/task/design/function

GF82.95-P-4100TMU