TELE AID switch-on/switch-off characteristics, function

Type gf · topic 82.95 · version 0100 · 2004-09-09

Applies to: MODEL 215.3, 220.0 /1 with CODE (383) TELE AID fixed installation telephone except CODE (494) USA version except CODE (498) Japan version

Where it sits

Function group 3 Body › 82 Electrical system, body › 82.95 Emergency call system — Series 215 (models 3**) · Series 220 (models 0**, 1**)

GF82.95-P-2000SE

TELE AID switch-on/switch-off characteristics, function

1.6.04

MODEL 215.3, 220.0 /1
with CODE (383) TELE AID fixed installation telephone
except CODE (494) USA version
except CODE (498) Japan version

Function requirements

Any telematics service has to be authorized separately. If there is a defect or if authorization is missing, an error message appears in the multifunction display (A1p13) of the instrument cluster (A1) and in the display of the COMAND operating, display and control unit (A40/3).

Self-test

With active circuit 15R, the telecommunications control unit (N112) executes a self-test (approx. 3.5 s). If the test is successful, the system is operational.

Terminating an emergency call

Usually, deactivation is carried out by the emergency call center.

Establishing a telephone connection in the event of an emergency call is aborted after 6 unsuccessful attempts to call by the telecommunications control unit (N112). In other words, there are 3 attempts to call the emergency call center and 3 additional attempts to call the fire department (911).

Telecommunications control unit, location/task/design/function

GF82.70-P-3114SU