gf8295p2000rm

TELE AID switch-on/switch-off characteristics, function

Type gf · topic 82.95 · version 0101 · 2008-04-10

Applies to: MODEL 230.4 as of 1.7.04 with CODE (359) TELE AID emergency call system with CODE (494) USA version up to Model Year 8

Where it sits

Function group 3 Body › 82 Electrical system, body › 82.95 Emergency call system — Series 230 (models 4**)

GF82.95-P-2000RM

TELE AID switch-on/switch-off characteristics, function

20.7.04

MODEL 230.4 as of 1.7.04
with CODE (359) TELE AID emergency call system
with CODE (494) USA version
up to Model Year 8

Function requirements

Each telematics service must be authorized separately. If there is a malfunction or if there is no authorization available, an error message is displayed on the left multifunction display (A1p13) and on the right multifunction display (A1p15) in the instrument cluster (A1) and on the screen of the COMAND operating, display and control unit (A40/3).

Self-test

When terminal 15R is active, the emergency call system control unit (N123/4) conducts a self-test (lasting approx. 3.5 s). If the self-test is successful, then the system is operational.

Ending an emergency call

An emergency call is normally ended by the emergency call center.

After several unsuccessful attempts to place an emergency call, this function is canceled in the emergency call system control unit (N123/4).

TELE AID control unit, location/task/design/function

GF82.95-P-4100RM

Referenced documents