gf8235p3003s

Windshield washer nozzle and windshield washer nozzle hose heater, function

Type gf · topic 82.35 · version 0102 · 1999-08-17

Applies to: MODEL 215, 220

Where it sits

Function group 3 Body › 82 Electrical system, body › 82.35 Windshield washing system — Series 215 · Series 220

GF82.35-P-3003S

Windshield washer nozzle and windshield washer nozzle hose heater, function

11.3.98

MODEL 215, 220

Washer nozzle and washer nozzle hose heater function
The heated windshield washer nozzle (R2/1) and washer nozzle hose heater (R2/11) are switched on automatically when:

C. 61 ON (engine: ON) and

outdoor temperature less than 5°C

is recognized.

Switch-off is accomplished:

C.61 OUT (engine: OFF) or

outdoor temperature greater than 7°C

are recognized.

If the values (outdoor temperature, c.61) are not present or not logical the heater elements are not switched on!

Control of heater elements
The heater elements for the heated windshield washer nozzle (R2/1) and washer nozzle hose heater (R2/11) are connected in parallel.
Control of the heated windshield washer nozzles (R2/1) and washer nozzle hose heater (R2/11) is accomplished directly from the right front SAM control module (N10/7). For this purpose the SAM completes circuit 30 to the heater elements.

Required data

The ambient temperature is recorded by the ambient temperature display temperature sensor (B14). The left front SAM control module (N10/6) reads in the sensor and sends the measured value as a message on the CAN (interior).

The status of c.61 (generator G2) is read in directly by the right front SAM control module (N10/7).

Left signal-acquisition and control module, location/purpose/design/function

GF54.21-P-4101S

Right signal-acquisition and control module, location/purpose/design/
function

GF54.21-P-4102S

Windshield washer, location of components

GF82.35-P-0001-01S

Outdoor temperature sensor, location/purpose/design/function

GF83.57-P-2103S

Referenced documents