gf8050p2003tx

Deactivate anti-theft alarm, function

Type gf · topic 80.50 · version 0100 · 2004-07-15

Applies to: MODEL 219.3 with CODE (551a) Anti-theft alarm system (ATA)

Where it sits

Function group 3 Body › 80 Central locking system, convenience operation, drive authorization systems › 80.50 Anti-theft alarm system (ATA), Interior motion sensor/Tow sensor — Series 219 (models 3**)

GF80.50-P-2003TX

Deactivate anti-theft alarm, function

26.5.04

MODEL 219.3 with CODE (551a) Anti-theft alarm system (ATA)

Deactivating anti-theft alarm system (ATA)

Unlocking central locking (CL) with transmitter key (A8/1) or

Inserting transmitter key (A8/1) into EIS control module (N73) or

Unlocking via keyless go (KG) (with code (889) Keyless Go)

The corresponding signals of the EIS control module (N73) are read in via the controller area network bus class B (passenger compartment) (CAN-B) by the rear SAM control module with fuse and relay module (N10/2) The rear SAM control module with fuse and relay module (N10/2) deactivates the ATA

Acoustic deactivation feedback (only )

The alarm signal siren with additional battery (H3/1) outputs acoustic feedback by buzzing a number of times.

Transmitter key component description

A8/1

GF80.57-P-6010TX

Rear SAM control module with fuse and relay module component description

N10/2

GF54.21-P-6030TX

Electronic ignition switch control module (EIS) component description

N73

GF80.57-P-6000TX

Alarm signal horn component description

H3/1

GF80.50-P-6020TX

Referenced documents