gf8050p2003pp

Deactivate anti-theft alarm system, function

Type gf · topic 80.50 · version 0105 · 2008-04-08

Applies to: MODEL 203.0 /2 /7 with CODE (551) Anti-theft alarm system (ATA [EDW]) up to Model Year 8

Where it sits

Function group 3 Body › 80 Central locking system, convenience operation, drive authorization systems › 80.50 Anti-theft alarm system (ATA), Interior motion sensor/Tow sensor — Series 203 (models 0**, 2**, 7**)

GF80.50-P-2003PP

Deactivate anti-theft alarm system, function

8.3.06

MODEL 203.0 /2 /7
with CODE (551) Anti-theft alarm system (ATA [EDW])
up to Model Year 8

The anti-theft alarm system (ATA) is deactivated by:

Unlocking vehicle with transmitter key (A8/1) or

Inserting transmitter key (A8/1) into EIS control module (N73)

By transmitting the signals "Global unlocking" or "Selective unlocking" or by recognizing a valid transmitter key (A8/1) in the EIS control module (N73) the anti-theft alarm system (ATA) is deactivated by the rear SAM control module with fuse and relay module (N10/2) and, if applicable, a triggered alarm is interrupted.

Feedback after successful deactivation (only and ):

The alarm signal horn with additional battery (H3/1) outputs an acoustic feedback by buzzing once.

Trunk lid remote control:

The trunk lid remote control function only disarms the anti-theft alarm system (ATA) partially.

The

Trunk lid rotary tumbler microswitch (S17/8)

ATA inclination sensor (B33) (as of 1.6.06 not and )

and with code (882) Interior monitoring (with ATA only) die

Interior protection transmitter and receiver (A26/14)

are excluded as alarm criterion.

The remaining anti-theft alarm system (ATA) remains activated.

After closing the trunk lid, the anti-theft alarm system (ATA) is returned to the status before opening.

Rear SAM control unit with fuse and relay module, location/task/design/function

GF54.21-P-4115PP

Transmitter key, task/design/function

GF80.57-P-4101PP

Electronic ignition switch control unit, location/task/design/function

GF80.57-P-4102PP

Referenced documents