Deactivating anti-theft alarm (ATA), function

Type gf · topic 80.50 · version 0106 · 1999-06-10

Applies to: MODEL 202 as of 1.6.97 up to 31.5.98, 208, 210.081 /281 up to 31.5.98, 210 (except 210.081 /281) as of 1.3.97 up to 31.5.98 with CODE (551a) Anti-theft alarm (ATA)

Where it sits

Function group 3 Body › 80 Central locking system, convenience operation, drive authorization systems › 80.50 Anti-theft alarm system (ATA), Interior motion sensor/Tow sensor — Series 202 · Series 208 · Series 210 (models 003, 004, 006, 007, 010, 015, 016, 017, 020, 025, 026, 035, 037, 045, 048, 053, 055, 061, 062, 063, 065, 070, 072, 074, 081, 082, 083, 206, 210, 215, 216, 217, 225, 226, 235, 237, 245, 248, 261, 262, 263, 265, 270, 272, 274, 281, 282, 283, 606, 610, 616, 617, 663)

GF80.50-P-2003B

Deactivating anti-theft alarm (ATA), function

15.1.97

MODEL 202 as of 1.6.97 up to 31.5.98,
208, 210.081 /281 up to 31.5.98,
210 (except 210.081 /281) as of 1.3.97 up to 31.5.98 with CODE (551a) Anti-theft alarm (ATA)

The anti-theft alarm (ATA) is deactivated by:

unlocking the vehicle centrally using the transmitter key

unlocking the vehicle centrally by opening a front door

unlocking the vehicle centrally via the lock switches (only , ).

The Pneumatic systems equipment (PSE) control module (combined) (A37) receives the command "unlock vehicle" via CAN and then deactivates all alarm inputs.

The ATA is not deactivated if the vehicle is unlocked

via the interior central locking switch (S6/1s2) or

via the emergency opening function.

Deactivating the ATA results in the cancelation of a previously triggered alarm.

Function of activating anti-theft alarm system (ATA)

without code 882 (interior motion sensor)

GF80.50-P-2002B

with code 882

GF80.50-P-2002C

Alarm triggering - function

GF80.50-P-2004B

PSE (combined) (A37) - arrangement/purpose/design/function

GF80.20-P-4106A

Unlocking by opening a door - function

GF80.20-P-3004A

Unlocking with transmitter key - function

GF80.20-P-3006A

Locking/unlocking with lock switch - function

GF80.20-P-3007A