GF80.45-P-2009PP | Convenience closing/opening with recirculated air pushbutton function | 2.12.99 |
MODEL 203 up to Model Year 8
Function requirements
Circuit 15 on
Windows normalized
No undervoltage/overvoltage
Function enabled via variant coding in the EIS [EZS]
Recirculated air pushbutton actuated for t longer than
1.5 sec.
Automatic window closing via recirculated air pushbutton
The position of the windows prior to the commencement of the closing sequence is stored.
It is kept in memory until circuit 15 is switched off.
If this function is requested again during or after completion of the closing sequence, then the initially stored position is retained.
To minimize relay noise, any window that is already in the upper end stop position will not be activated.
-----------------------------------------------------------------------------------------
Automatic window opening via recirculated air pushbutton
The function can be activated if automatic closing via the recirculated air pushbutton was performed beforehand after circuit 15 "ON".
The windows open automatically as far as the stored position if the current window position is at least 8 Hall pulses above the stored opening position.
A window will not be activated if it is positioned less than 8 Hall pulses above the stored opening position, or if it has in the meantime been lowered to below the stored position.
If automatic closing via the recirculating air pushbutton is initiated again while the window is opening, but before it has reached its stored position, the opening position initially stored will be retained in memory.
-----------------------------------------------------------------------------------------
The automatic window closing via recirculating air pushbutton function will be aborted if
Function requirements not satisfied
The power window operating switch is activated in either direction
An obstruction is detected
There is a response from the excess force limiter (obstruction sensor)
Zero point tolerance exceeded
The automatic window opening via recirculating air pushbutton function will be aborted if
Function requirements not satisfied
The power window operating switch is activated in either direction
An obstruction is detected
The maximum window travel is exceeded
The window positions stored for the function of convenience closing via the recirculated air pushbutton are erased when the ignition is switched off.
Convenience opening of power windows function | |||
Convenience closing of power windows function | |||
Convenience opening of sliding/tilting roof function | Model 203.0/203.2 | ||
Convenience closing of sliding/tilting roof function | Model 203.0/203.2 | ||
Automatically raise/lower power windows function | |||
Automatic opening/closing of sliding/tilting roof function | Model 203.0/203.2 |
Referenced documents
- gf7229p3004pp Convenience opening of power windows, function
- gf7229p3005pp Convenience closing of power windows, function
- gf7229p3007pp Automatic raising/lowering power windows, function
- gf7720p2000pp Convenience opening of sliding/pop-up roof, function
- gf7720p2001pp Convenience closing of sliding/pop-up roof, function
- gf7720p2008pp Automatic opening/closing of sliding/pop-up roof, function