Convenience closing/opening with recirculated air pushbutton function

Type gf · topic 80.45 · version 0102 · 2008-04-08

Applies to: MODEL 203 up to Model Year 8

Where it sits

Function group 3 Body › 80 Central locking system, convenience operation, drive authorization systems › 80.45 Convenience feature (CF)/Convenience locking system — Series 203

GF80.45-P-2009PP

Convenience closing/opening with recirculated air pushbutton function

2.12.99

MODEL 203 up to Model Year 8

Function requirements

Circuit 15 on

Windows normalized

No undervoltage/overvoltage

Function enabled via variant coding in the EIS [EZS]

Recirculated air pushbutton actuated for t longer than
1.5 sec.

Automatic window closing via recirculated air pushbutton

The position of the windows prior to the commencement of the closing sequence is stored.

It is kept in memory until circuit 15 is switched off.

If this function is requested again during or after completion of the closing sequence, then the initially stored position is retained.

To minimize relay noise, any window that is already in the upper end stop position will not be activated.

-----------------------------------------------------------------------------------------

Automatic window opening via recirculated air pushbutton

The function can be activated if automatic closing via the recirculated air pushbutton was performed beforehand after circuit 15 "ON".

The windows open automatically as far as the stored position if the current window position is at least 8 Hall pulses above the stored opening position.

A window will not be activated if it is positioned less than 8 Hall pulses above the stored opening position, or if it has in the meantime been lowered to below the stored position.

If automatic closing via the recirculating air pushbutton is initiated again while the window is opening, but before it has reached its stored position, the opening position initially stored will be retained in memory.

-----------------------------------------------------------------------------------------

The automatic window closing via recirculating air pushbutton function will be aborted if

Function requirements not satisfied

The power window operating switch is activated in either direction

An obstruction is detected

There is a response from the excess force limiter (obstruction sensor)

Zero point tolerance exceeded

The automatic window opening via recirculating air pushbutton function will be aborted if

Function requirements not satisfied

The power window operating switch is activated in either direction

An obstruction is detected

The maximum window travel is exceeded

The window positions stored for the function of convenience closing via the recirculated air pushbutton are erased when the ignition is switched off.

Convenience opening of power windows function

GF72.29-P-3004PP

Convenience closing of power windows function

GF72.29-P-3005PP

Convenience opening of sliding/tilting roof function

Model 203.0/203.2

GF77.20-P-2000PP

Convenience closing of sliding/tilting roof function

Model 203.0/203.2

GF77.20-P-2001PP

Automatically raise/lower power windows function

GF72.29-P-3007PP

Automatic opening/closing of sliding/tilting roof function

Model 203.0/203.2

GF77.20-P-2008PP