gf8020p2003a

Headlamp illumination feature, function

Type gf · topic 80.20 · version 0102 · 1998-06-13

Applies to: MODEL 202 as of 1.6.97, 208, 210.081 /281, 210 (except 210.081 /281) as of 1.3.97 with CODE (491) USA version

Where it sits

Function group 3 Body › 80 Central locking system, convenience operation, drive authorization systems › 80.20 Central locking system, interior central locking — Series 202 · Series 208 · Series 210 (models 003, 004, 006, 007, 010, 015, 016, 017, 020, 025, 026, 035, 037, 045, 048, 053, 055, 061, 062, 063, 065, 070, 072, 074, 081, 082, 083, 206, 210, 215, 216, 217, 225, 226, 235, 237, 245, 248, 261, 262, 263, 265, 270, 272, 274, 281, 282, 283, 606, 610, 616, 617, 663)

GF80.20-P-2003A

Headlamp illumination feature, function

17.1.97

MODEL 202 as of 1.6.97,
208, 210.081 /281,
210 (except 210.081 /281) as of 1.3.97 with CODE (491) USA version

The headlamp illumination feature serves for illuminating
the surrounding area, e.g. in an underground parking lot, for
a short time after leaving the vehicle.

Activating function

Switch on ignition with headlamp switched on and door open. The PSE control module (combined) (A37) recognizes the voltage potential of the rear lamps and sets the function status to "active" as soon as circuit 15 on is recognized via the CAN bus.

After the last vehicle door is closed the fog lamps switch on for a certain time. The time they are switched on can be set up to max. 120 seconds with the version coding of the PSE control module.

-----------------------------------------------------------------------------------------

Deactivating function

Switch on the ignition with the headlamps switched off and door open. The PSE control module (combined) (A37) sets the function status to "inactive" as soon as circuit 15 on is recognized via
the CAN bus.

The function is also deactivated by

tripping off the anti-theft alarm (ATA) or

setting the ATA to the diagnostic mode

during the illumination period.

-----------------------------------------------------------------------------------------

Anti-theft alarm (ATA)

up to 5/98

GF80.50-P-0001B

as of 6/98

GF80.50-P-0001F

PSE control module (combined), location/purpose/design/function

GF80.20-P-4106A

Referenced documents