GF77.20-P-3003A | Tilting/sliding roof denormalization function | 23.1.97 |
MODELS 202 as of 1.6.97,
208, 210.081 /281 (except 208.4),
210 (except 210.081 /281) as of 1.3.97
Definition
Through denormalization the normalization of the tilting/sliding roof is canceled, in other words the counter state is invalidated for the position measurement.
Function
Denormalization occurs when
the overhead control panel control module (N70) was disconnected from the supply voltage (e.g. by disconnecting the battery, removal/installation of the control module), or
-----------------------------------------------------------------------------------------
an error in the position measurement is detected or
lock-up of the drive is detected.
In all of these cases, there is no longer any correspondence between the counter state of the position measurement and the actual position of the tilting/sliding roof. Therefore, normalization must be performed again.
-----------------------------------------------------------------------------------------
Referenced documents
- gf7720p3001a Sliding/pop-up roof position measurement, function
- gf7720p3002a Sliding/pop-up roof synchronization, function
- gf8220p4101a Overhead control panel control module, location/purpose/design/function