GF77.20-P-2012PC | Close panoramic sliding roof function | 27.9.00 |
MODEL 203.7
with CODE (413) Panoramic sliding roof
up to Model Year 8
Function requirements
No overvoltage/undervoltage
Circuit 15R ON or
Circuit 15 ON and
The overhead control panel control module (N70) recognizes the neutral position before switch is activated
(no activation within 1 second)
Function
The "close panoramic sliding roof" function is only available when the panoramic sliding roof is in the normalized state.
It is deployed by moving the roof system switch (N70s1) toward the front of the vehicle. The roof system switch (N70s1) must remain manually pressed. The overhead control panel control module (N70) then actuates the roof system motor (M12m1), which closes the panoramic sliding roof. The motor operates for as long as the switch is activated or until the panoramic sliding roof reaches its end position.
The "close panoramic sliding roof" function is aborted if a lock-up of the panoramic sliding roof is detected. The panoramic sliding roof is not equipped with an obstruction sensor.
Referenced documents
- gf7720p2014pc Open panoramic sliding roof function
- gf7720p3007pc Panoramic sliding roof lock-up recognition function
- gf7720p3009pc Panoramic sliding roof normalization function
- gf7720p4104pc Panoramic sliding roof location/task/design/function
- gf8220p4101pp Overhead control panel control unit, location/task/design/function