Closing sliding/pop-up roof, function

Type gf · topic 77.20 · version 0100 · 2002-10-11

Applies to: MODEL 240 with CODE (414A) Electric glass sliding/pop-up roof

Where it sits

Function group 3 Body › 77 Sliding roof, soft top, top attachments › 77.20 Electric sliding roof — Series 240

GF77.20-P-2002MX

Closing sliding/pop-up roof, function

15.8.02

MODEL 240 with CODE (414A) Electric glass sliding/pop-up roof

Function requirements:

No overvoltage or undervoltage

Circuit 15R ON or

Circuit 15 ON and

The overhead control panel control module (N70) recognizes the neutral position before the switch is actuated.

(switch was not activated for longer than 40 ms)

Operation

The "close sliding/pop-up roof" function is only available when the sliding/pop-up roof is in the synchronized state. It is

actuated by pulling the roof system switch (N70s1) down to the first catch. The overhead control panel control module (N70) then actuates the sliding/pop-up roof motor (M12m1). The direction in which the motor is actuated depends on whether the sliding roof or the pop-up roof is open. The motor is actuated for as long as the switch is activated, though for no longer than 50 s (max. activation time). The "close sliding/pop-up roof" function is aborted if the sliding/pop-up roof is detected to lock up or if an obstruction is detected.

Automatic opening/closing of sliding/pop-up roof, function

GF77.20-P-2008MX

Sliding/pop-up roof opening, function

GF77.20-P-2009MX

Sliding/pop-up roof lock-up recognition, function

GF77.20-P-3000MX

Synchronizing sliding/pop-up roof, function

GF77.20-P-3002MX

Sliding/pop-up roof obstruction sensor, function

GF77.20-P-3004MX

Sliding/pop-up roof motor, location/purpose/design/function

GF77.20-P-4105MX

Overhead control panel control module, location/purpose

GF82.20-P-4120MX

Referenced documents