gf7229d2012h

Actuate electric load component sliding door (E-LST), function

Type gf · topic 72.29 · version 0101 · 2009-02-24

Applies to: MODEL 906.611 /613 /631 /633 /635 /637 /653 /655 /657 /711 /713 /731 /733 /735 with CODE (T55) Electrical actuation for right sliding door Outside door handle MODEL 906.611 /613 /631 /633 /635 /637 /653 /655 /657 /711 /713 /731 /733 /735 with CODE (T56) Electrical actuation for left sliding door Outside door handle

Where it sits

Function group 3 Body › 72 Doors › 72.29 Doors - electrical system — Series 906 (models 611, 613, 631, 633, 635, 637, 653, 655, 657, 711, 713, 731, 733, 735)

GF72.29-D-2012H

Actuate electric load component sliding door (E-LST), function

13.2.09

MODEL 906.611 /613 /631 /633 /635 /637 /653 /655 /657 /711 /713 /731 /733 /735 with CODE (T55) Electrical actuation for right sliding door
Outside door handle

MODEL 906.611 /613 /631 /633 /635 /637 /653 /655 /657 /711 /713 /731 /733 /735 with CODE (T56) Electrical actuation for left sliding door
Outside door handle

Function requirements for opening:

No overvoltage or undervoltage

Outside door handle actuated once

When the outer door handle is actuated with the vehicle locked, the electric load compartment sliding door (E-LST) is unlocked mechanically (self-ejection).

Opening sequence:

Microswitch in outer door handle transmits to the right sliding door control unit (N69/6) or left sliding door control unit (N69/7) the

- signal "Open door"

Right sliding door control unit or left sliding door control unit to opening assist

- signal "Open E-LST lock"

-----------------------------------------------------------------------------------------

E-LST lock to right sliding door control unit or left sliding door control unit

- signal "Lock actuated" of right sliding door CL rotary tumbler switch (M14/27s1) or left sliding door CL rotary tumbler switch (M14/28s1)

Right sliding door control unit or left sliding door control unit to right sliding door drive (M73/1) or left sliding door drive (M73/2)

- The right sliding door drive or left sliding door drive moves the E-LST in the "E-LST open" position

The anti-pinch protection is active during the complete opening path.

-----------------------------------------------------------------------------------------

Function requirements for closing:

No overvoltage or undervoltage

Outside door handle actuated once

Closing sequence:

Microswitch in outside door handle transmits to the right sliding door control unit or left sliding door control unit the

- signal "Close door"

Right sliding door control unit or left sliding door control unit to right sliding door drive or left sliding door drive

- The right sliding door drive or left sliding door drive moves the E-LST in the "E-LST closed" position

E-LST lock to right sliding door control unit or left sliding door control unit

- signal "Door closed" of right sliding door CL rotary tumbler switch or left sliding door CL rotary tumbler switch to right sliding door control unit or to left sliding door control unit

The anti-pinch protection is active up to the pre-locking position.

Transmitter key, component description

With 3 buttons

GF80.57-D-6010HA

Sliding door drive, component description

GF72.29-D-4015H

Electric load compartment sliding door (E-LST) control unit, component description

GF72.29-D-4014H

Referenced documents