GF68.50-P-2005PC | Lock-up recognition function | 11.10.00 |
MODEL 203.7 with CODE (413) Panorama-Schiebedach
Panoramic sliding roof lock-up recognition function
The overhead control panel control module (N70) receives the voltage pulses sent by the two Hall sensors on the sun blind motor (M24m1), Hall sensor 1 (M24b1) and
Hall sensor 2 (M24b2), and uses this data for position measurement.
If no Hall sensor pulses are received for more than 0.2 seconds during sun blind actuation the drive unit is deactivated.
Hall sensor failure represents a denormalization.
The sun blind can then only be closed in increments of t = 160 ms by means of the roof system switch (N70s1), or alternatively by using the emergency crank.
Overload protection is provided by a mechanical thermal circuit breaker installed in the sun blind motor (M24m1).
Referenced documents
- gf6850p2006pc Position measurement function
- gf6850p2008pc Denormalization function
- gf6850p4101pc Panoramic sliding roof roller blind location/task/design/function
- gf8220p4101pp Overhead control panel control unit, location/task/design/function