gf0752s1008a

Fuel pump relay position/task/design/function

Type gf · topic 07.52 · version 0100 · 1999-11-02

Applies to: ENGINE 111 in MODEL 638

Where it sits

Function group 1 Engine › 07 Mixture formation › 07.52 PEC-SFI fuel injection/ignition system — Series 638

Also applies to engines/gearboxes: 111 ***

GF07.52-S-1008A

Fuel pump relay position/task/design/function

26.4.99

ENGINE 111 in MODEL 638

Fuel pump relay position/task/design/function

S07.52-3030-12

Task

Actuating the fuel pump

Design/function

The fuel pump (M18) is actuated by the PEC control module (A13) through unfused terminal 15 (switch on ignition) for about 1second. If the PEC control module (A13) detects engine speed, the fuel pump relay (K39) and thus the fuel pump (M18) are actuated constantly. No speed information signal results in the fuel pump relay (K39) and the fuel pump (M18) being switched off.

The fuel pump relay (K39) closes the power circuit to the fuel pump (M18). The power circuit to the fuel pump (M18) is protected by fuse (F61).

A13 PEC control module

A37 Fuel tank sensor module with integrated fuel pump (M18)

K39 Fuel pump relay

F61 Fuse (20 A)

M18 Fuel pump