P91.60-3146-09
Shown on right backrest |
1 | Cover | 5 | Bracket | |
2 | Electrical connector | 6 | Guides | |
3 | Rivet | 7 | Bracket | |
4 | Ground cable | 8 | Sidebag unit |
Warning | Risk of injury during testing and repair operations related to pyrotechnical components | Do not expose pyrotechnical component parts to temperatures above 100 °C or 212 °F. Disconnect current supply when working on such component parts. | |
Topical note | Information on preventing damage to electronic components due to electrostatic discharge | ||
Information, assessment and legal requirements when working with, handling and storing pyrotechnical components | |||
| Remove/install | ||
1 | Switch off ignition and store transmitter key outside of transmission range (min. 2 m) | ||
2 | Move front seat as far forward as it will go | ||
3 | Fold backrest forward | ||
4 | Disconnect battery ground line | ||
5 | Loosen cover (1) of backrest until sidebag unit (8) is accessible | ||
6 | Release and disconnect electrical connection (2) | ||
7 | Remove rivet (3) | ||
8 | Remove ground line (4) | ||
9 | Remove bracket (7) | ||
10 | Check the bracket (7) for damage | If the bracket (7) is damaged. | |
| |||
Remove cover (1). | |||
11 | Extend the brackets (5) of the sidebag unit (8) out of the guides (6) | ||
12 | Remove sidebag unit (8) | ||
13 | Install in the reverse order | ||
| Check | ||
14 | Read out the fault memory using the diagnostic system and clear if necessary | After replacing sidebag unit (8). | |
|
Referenced documents
- ad0000p200004a Connect STAR DIAGNOSIS and read out fault memory
- ad0000p200004a
- ah5400p000101a Information on preventing damage to electronic components due to electrostatic discharge
- ah9100z000010a Information, assessment and legal requirements when working with, handling and storing pyrotechnical components
- ar5410p0003rt Disconnect/connect battery ground line
- ar9118p1870rt Remove and install rear seat backrest cover
- ar9118p1870rtb Remove and install rear seat backrest cover
- as9100z000801a Risk of injury during testing and repair operations related to pyrotechnical components