1 | Front passenger airbag |
2 | Security catch |
3 | Electrical connector |
4 | Bolts |
5 | Cross member |
R12/4 | Front passenger airbag squib 1 |
R12/5 | Passenger airbag squib 2 |
P91.60-2440-06
Warning | Risk of injury during testing and repair operations related to pyrotechnical components | Do not expose pyrotechnical component parts to temperatures above 100 °C or 212 °F. Disconnect current supply when working on such component parts. | |
Topical note | Notes on self-locking nuts and bolts | ||
Topical note | Information on preventing damage to electronic components due to electrostatic discharge | ||
Information, assessment and legal requirements when working with, handling and storing pyrotechnical components | |||
| Remove/install | ||
1 | Switch off ignition and store transmitter key outside of transmission range (min. 2 m) | ||
2 | Remove top part of dashboard | ||
3 | Release lock tabs (2) and disconnect electrical connector (3) from front passenger airbag squib 1 (R12/4) and front passenger airbag squib 2 (R12/5) | Removal lever | |
Danger | Risk of fire and explosion caused by machining/treating magnesium components | Keep away from ignition sources and open flames. | |
4 | Remove bolts (4) | ||
Topical note | Information on machining/treating magnesium components | ||
Cross member (5) is made of a magnesium alloy. | |||
Bolt, front passenger airbag unit to instrument panel carrier | |||
5 | Remove front passenger airbag (1) from cross member (5) | ||
6 | Install in the reverse order | ||
| Check | ||
7 | Check and erase vehicle fault memory using diagnostic system | After replacing front passenger airbag (1). | |
|
203 589 04 33 00
Removal lever
Referenced documents
- ad0000p200004a Connect STAR DIAGNOSIS and read out fault memory
- ad0000p200004a
- ah0000n000101a Notes on self-locking nuts and bolts
- ah5400p000101a Information on preventing damage to electronic components due to electrostatic discharge
- ah6000p002301r Information on machining/treating magnesium components
- ah9100z000010a Information, assessment and legal requirements when working with, handling and storing pyrotechnical components
- ar6810p1020t Remove/install instrument panel upper section
- as6000z000601r Risk of fire and explosion caused by machining/treating magnesium components
- as9100z000801a Risk of injury during testing and repair operations related to pyrotechnical components