T88.80-0023-09
| Removing | ||
Danger! | Risk of poisoning after inhaling vapors or swallowing adhesive. Risk of injury from skin and eye contact with glue | Wear protective respiratory mask, protective gloves and safety glasses. Pour adhesive only into suitable and appropriately marked containers. | |
1 | Unscrew mounting screws (4) and remove rain strip (1) | Have helpers support rain strip. | |
| Installing | ||
2 | Remove residues of adhesive tape and sealing glue | | |
3 | Clean area to be glued with activator | Allow contact surfaces to air dry for at least 15 min. | |
Activator | |||
4 | Attach double-sided adhesive tape (2) to top of rain strip | ||
5 | Apply thin bead of sealing glue (3) next to adhesive tape | Sealant | |
6 | Align rain strip (1) and screw on | Have helper support rain strip. |
Repair materials
Number | Designation | Order number |
BR00.45-Z-1013-02A | Sealant 221, 310 ml, DB supply specification 6069.20 | A 001 989 64 20 |
BR00.45-Z-1023-04A | Sika activator | A 005 989 58 71 |
Referenced documents
- as0000z001601a Risk of poisoning caused by inhaling vapors or swallowing adhesive. Risk of injury caused by adhesive coming into contact with skin and eyes