AR86.30-D-0071A | Check sewer system for leakage | 19.5.04 |
MODEL 903.662
with CODE (ZU8) National version for USA
with CODE (Z29) "James Cook" touring camper, NAFTA
D54.65-1121-09
1 Caps
3 Cover
2 Bolts
D86.30-0089-06
4 Curtain
10 Pipe line
D86.30-0090-01
5 Strainer
6 Waste trap
D86.30-0092-05
7 Overflow pipe
D86.30-0094-05
8 Pipe line
D86.30-0095-01
9 Pipe line
D86.30-0098-08
11 Pipelines
| Check | ||
Danger! | Risk of injury caused by hot water exiting from the lines of the fresh water system | Shut off the water heater in a timely manner before starting repair work. Let the water in the lines and in the components of the fresh water system cool down to room temperature. | |
1 | Remove caps (1) | ||
2 | Unscrew bolts (2) | ||
3 | Take out cover (3) | ||
4 | Remove curtain (4) | ||
5 | Remove sieve (5) from waste trap (6) in shower tray | ||
6 | Plug waste trap (6) in shower tray | ||
7 | Plug overflow pipe (7) | ||
8 | Fill wastewater tank through boiler/sink combination and toilet | Add water until water no longer drains out of boiler/sink combination and toilet | |
9 | Fill sanitary block wash basin | Add water until water no longer drains out of wash basin | |
10 | Check entire pipeline (8) below boiler/sink combination for leakage, seal if necessary | ||
11 | Check entire pipeline (9) below sanitary block wash basin for leakage, seal if necessary | ||
12 | Check entire pipeline (10) in wardrobe for leakage, seal if necessary | ||
13 | Check pipelines (11) behind excrement tank for leakage, seal if necessary | ||
14 | Install in the reverse order | ||
15 | Drain wastewater tank | See Operator's Manual |
Referenced documents
- as8600z000201a Risk of injury caused by hot water exiting from the lines of the fresh water system