ar8630d0064ecc

Remove/install water rain shut-off lever

Type ar · topic 86.30 · version 0100 · 2005-08-11

Applies to: MODEL 903.6 with CODE (ZL9) "James Cook" touring camper of wastewater tank

Where it sits

Function group 3 Body › 86 Emergency equipment, diability equipment, sanitary equipment, galley › 86.30 Sanitary equipment — Series 903 (models 6**)

EinPAS 37 Interior equipment › 37.75 Sanitary equipment › 37.75.30 Sanitary installations — Series 903 (models 6**)

AR86.30-D-0064ECC

Remove/install water rain shut-off lever

28.4.05

MODEL 903.6 with CODE (ZL9) "James Cook" touring camper
of wastewater tank

Remove/install water rain shut-off lever

D86.30-0199-09

1 Drain valve bottom section

2 Drain valve top section

3 Threaded connection

6 Sewer pipe

7 Connector

4 Bolt

5 Flexible shaft

Remove/install

Danger!

Risk of death caused by vehicle slipping or toppling off of the lifting platform.

Align vehicle between the columns of the lifting platform and position the four support plates at the lifting platform support points specified by the vehicle manufacturer.

AS00.00-Z-0010-01A

1

Drain wastewater tank

See Owner's manual.

2

Remove cable tie from sewer pipe (6)

Installation: Use new cable ties.

3

Remove sewer pipe (6)

Sewer pipe (6) is inserted into drain valve bottom section (1)

4

Remove bolt (4)

5

Pull flexible shaft (5) out of coupling (7)

6

Unscrew threaded connection (3)

Use suitable tool to unscrew screwed connection (3).

7

Remove drain valve bottom section (1)

8

Unscrew drain valve top section (2)

It is not possible to unscrew the drain valve top section (2) without damage

Installation: Replace drain valve top section (2), use suitable sealing tape and suitable glue.

9

Install in the reverse order

Referenced documents