Remove/install water rain shut-off lever

Type ar · topic 86.30 · version 0100 · 2005-08-11

Applies to: MODEL 903.6 with CODE (ZL9) "James Cook" touring camper of hot water boiler

Where it sits

Function group 3 Body › 86 Emergency equipment, diability equipment, sanitary equipment, galley › 86.30 Sanitary equipment — Series 903 (models 6**)

EinPAS 37 Interior equipment › 37.75 Sanitary equipment › 37.75.30 Sanitary installations — Series 903 (models 6**)

AR86.30-D-0064ECA

Remove/install water rain shut-off lever

27.4.05

MODEL 903.6 with CODE (ZL9) "James Cook" touring camper
of hot water boiler

Remove/install water rain shut-off lever

D86.30-0194-09

1 Drain valve

2 Hose clamp

5 Hose

6 Bolts

3 Hose clamps

4 Hoses

Remove/install

1

Switch off water pump

See Owner's manual.

2

Open drain valve (1)

See Owner's manual.

Wait until water stops running out

3

Mark position of hoses (4, 5)

To prevent mix-up when installing.

4

Loosen hose clamps (3)

Check condition of hose clamps (3) and replace if necessary to prevent leakages.

5

Detach hoses (4)

Check condition of hoses (4) and replace if necessary to prevent leakage.

6

Slacken hose clamp (2)

Check condition of hose clamp (2) and replace if necessary to prevent leakage.

7

Pull off hose (5)

Check condition of hose clamp (5) and replace if necessary to prevent leakage.

8

Remove bolts (6)

9

Remove drain valve (1)

10

Install in the reverse order

11

Fill hot water boiler (A99)

See Owner's manual.