ar8630d0042a

Remove/install city water connection check valve

Type ar · topic 86.30 · version 0100 · 2004-11-03

Applies to: MODEL 903.662 with CODE (ZU8) National version for USA with CODE (Z29) "James Cook" touring camper, NAFTA

Where it sits

Function group 3 Body › 86 Emergency equipment, diability equipment, sanitary equipment, galley › 86.30 Sanitary equipment — Series 903 (models 662)

EinPAS 37 Interior equipment › 37.75 Sanitary equipment › 37.75.13 Line/hose/valve — Series 903 (models 662)

AR86.30-D-0042A

Remove/install city water connection check valve

8.7.04

MODEL 903.662
with CODE (ZU8) National version for USA
with CODE (Z29) "James Cook" touring camper, NAFTA

Remove/install city water connection check valve

D86.30-0131-09

2 Pressure reducing valve

5 Housing

3 Check valve

Remove/Install

1

Remove city water connection

AR86.30-D-0040A

2

Remove city water connection pressure reducing valve

AR86.30-D-0041A

3

Unscrew check valve (3) from housing (5) city water connection

Installation: Observe installation position of check valve (3) (arrow on component)

Installation: Use suitable thread sealant

4

Install in the reverse order

5

Check fresh water system for leakage

AR86.30-D-0065A

Referenced documents