AR86.30-D-0042A | Remove/install city water connection check valve | 8.7.04 |
MODEL 903.662
with CODE (ZU8) National version for USA
with CODE (Z29) "James Cook" touring camper, NAFTA
D86.30-0131-09
2 Pressure reducing valve
5 Housing
3 Check valve
| Remove/Install | ||
1 | Remove city water connection | ||
2 | Remove city water connection pressure reducing valve | ||
3 | Unscrew check valve (3) from housing (5) city water connection | Installation: Observe installation position of check valve (3) (arrow on component) | |
Installation: Use suitable thread sealant | |||
4 | Install in the reverse order | ||
5 | Check fresh water system for leakage |