AR86.30-D-0039ECB | Remove/install check valve | 3.5.05 |
MODEL 903.6 with CODE (ZL9) "James Cook" touring camper
In water line to hot water boiler
D86.30-0180-06
1 Hose clamps
2 Hoses
3 Check valve
| Remove/install | ||
1 | Switch off water pump | See Owner's manual. | |
2 | Drain hot water boiler (A99) | See Owner's manual. | |
3 | Release hose clamps (1) | Installation: Replace hose clamps (1) to prevent leakages. | |
4 | Disconnect hoses (2) | Mark installation position of check valve (3) to ensure proper function of fresh water system. | |
5 | Remove check valve (3) | ||
6 | Install in the reverse order | ||
7 | Fill hot water boiler (A99) | See Owner's manual. |