AR83.70-P-5700A | Remove/install coolant circulation pump | 30.11.09 |
MODEL 210.### 1# up to 636643 with ENGINE 604, 605, 606 with CODE (228) Stationary heater
Thermo Top S heater
MODEL 210.### 1# up to 672083 with ENGINE 104, 111, 112, 113, 119 with CODE (228) Stationary heater
Thermo Top S heater
MODEL 202 up to 31.5.97
retrofitted Thermo Top S stationary heater
P83.70-0221-12
1 Screw
2 Flange
3 Clutch
4 Sealing ring
5 Burner housing
6 Heat-transfer unit control unit
A6m1 Circulation pump
| Remove/install | ||
1 | Remove heater unit | Model 202 | |
Model 210 | |||
2 | Remove flame monitor/glow pin | ||
3 | Remove burner | ||
4 | Remove combustion air blower unit | ||
5 | Remove screws (1) | | |
6 | Pull circulation pump (A6m1) out of burner housing (5) | Installation: Guide connection line upwards of circulation pump and combustion air blower at burner housing in cutout next to coolant outlet fitting. Do not pinch or crush the connection lines. | |
7 | Remove flange (2) and sealing ring (4) from circulation pump | Installation: When changing the circulation pump, replace sealing ring (4), screws/bolts (1) and flange (2). | |
8 | Install in the reverse order |
Stationary heater
Referenced documents
- ar8370p5302a Removing and installing stationary heater
- ar8370p5302ap Removing and installing stationary heater
- ar8370p5555a Remove/install combustion air blower unit
- ar8370p5742a Remove/install flame monitor/glow pin
- ar8370p5770a Removing and installing burner