ar8370d5744b

Remove/install combination overheating/flame sensor

Type ar · topic 83.70 · version 0100 · 2006-12-20

Applies to: MODEL 906 with CODE (H11) Warm air auxiliary heater

Where it sits

Function group 3 Body › 83 Climate control › 83.70 Auxiliary/supplementary heater — Series 906

EinPAS 39 Heating/ventilation/cooling › 39.25 Stationary heater/auxiliary heater › 39.25.12 Sensor/switch/wiring harness — Series 906

AR83.70-D-5744B

Remove/install combination overheating/flame sensor

5.12.06

MODEL 906 with CODE (H11) Warm air auxiliary heater

Remove/install combination overheating/flame sensor

D83.70-1287-09

1 Cover

2 Casing housing

3 Locking bracket

7 Auxiliary heating control unit

8 Plug for combination sensor connection lines

9 Combination sensor connection lines

4 Locking clamp

5 Combination overheating/flame sensor

6 Heat exchanger

Remove/install

1

Remove auxiliary heater control unit (7)

Only lift up control unit, do not disconnect lines.

AR83.70-D-5937H

2

Detach plug for combination sensor connection lines (8) from auxiliary heater control unit (7)

3

Release locking clamp (4)

Installation: Route combination sensor connection lines (9) through eyelet of locking clamp (4) (arrow).

4

Remove combination overheating/flame sensor (5) from heat exchanger (6)

Installation: Slide combination sensor underneath jacket housing until it reaches the end stop. Check installation position of combination sensor. The combination sensor must be flush with heat exchanger, correct the position of combination sensor if necessary.

5

Install in the reverse order