AR83.70-D-5652I | Remove/install fuel metering pump | 5.12.06 |
MODEL 906.6 /7 with CODE (H11) Warm air auxiliary heater
AIRTRONIC D4S heater unit
D83.70-1430-09
Shown on model 906.7
21 Preheating hose
22 Warm air auxiliary heater connection line
23 Mounting bolts
27 Intake air hose
28 Combustion air hose
29 heater housing
Y23/4 Metering pump
24 Fuel line, thrust side
25 Metering pump bracket
26 Fuel line on tank side
| Remove/install | ||
Danger! | Risk of explosion caused by fuel igniting, risk of poisoning caused by inhaling and swallowing fuel and risk of injury to eyes and skin caused by contact with fuel | No fire, sparks, open flames or smoking. Wear protective clothing when handling fuel. | |
1 | Detach fuel line on tank side (26) | Collect fuel which flows out. | |
2 | Detach fuel line on thrust side (24) | Collect fuel which flows out. | |
3 | Disconnect electrical connector from metering pump (Y23/4) | ||
4 | Pull metering pump (Y23/4) out of metering pump bracket (25) | ||
5 | Install in the reverse order |
Referenced documents
- as4700z000101a Risk of explosion caused by fuel igniting, risk of poisoning caused by inhaling and swallowing fuel as well as risk of injury to eyes and skin caused by contactwith fuel.