Shown on model 613.455 with code HKB (Konvekta ACX 641 SAPTCO A/C without roof heater) |
1 | Refrigerant compressor |
2 | Pressure-side shutoff valve |
3 | High-pressure connection |
4 | Low-pressure connection |
5 | Intake-side shutoff valve |
6 | Low-pressure connection |
7 | Intake-side shutoff valve |
T83.30-0073-06
Shown on model 613.455 with code HKB (Konvekta ACX 641 SAPTCO A/C without roof heater) |
1 | Refrigerant compressor |
8 | Drip tray |
9 | Electrical connector |
10 | Carrier |
T83.55-0018-06
| Remove/install | ||
Danger | Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained. | |
Topical note | Procedure for a damaged or leaky air conditioning system | ||
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Notes on handling refrigerant R134a | |||
1 | Open liftgate | ||
2 | Remove rear bumper | ||
3 | Remove V-belt from refrigerant compressor | ||
4 | Fuel prefilter with water separator - Remove filter element | ||
| |||
5 | Remove collecting pan (8) | ||
6 | Disconnect electrical connector (9) of magnetic clutch | ||
7 | Remove protective cap over pressure-side shutoff valve (2) and protective caps over intake-side shutoff valves (5, 7) | ||
8 | Drain air conditioning system | ||
9 | Screw in pressure-side shutoff valve (2) and intake-side shutoff valves (5, 7) completely | Screwing in the pressure side shutoff valve (2) and the intake-side shutoff valves (5, 7) prevents moisture from entering the system. | |
10 | Remove screws connecting high-pressure connection (3) to refrigerant compressor (1) | ||
| Compressor oils (specification 362.0) | ||
Installation: Use new seals. Coat seals with compressor oil before installation. | |||
Bolt of high and low pressure connection to refrigerant compressor | |||
Torque wrench | |||
11 | Remove screws connecting low-pressure connection (4, 6) to refrigerant compressor (1) | ||
| Compressor oils (specification 362.0) | ||
Installation: Use new seals. Coat seals with compressor oil before installation. | |||
Bolt of high and low pressure connection to refrigerant compressor | |||
Torque wrench | |||
12 | Remove screws connecting refrigerant compressor (1) to carrier (10) | Counterhold nuts from below. | |
Bolt, refrigerant compressor to carrier | |||
Torque wrench | |||
13 | Remove refrigerant compressor (1) | ||
14 | Install in the reverse order | ||
15 | Evacuate air conditioning system | ||
16 | Fill air conditioning system | ||
17 | Perform function test | ||
| Air conditioning system - function check | Model NMB613.455 with engine 446.938 | |
| Air conditioning system - function check | Model NMB613.455 with engine 446.938 |
001 589 67 21 00
Torque wrench
Referenced documents
- ah8330n000301a Notes on handling refrigerant R134a
- ah8330n000401a Procedure for a damaged or leaky air conditioning system
- ah8330n000501a Protect air conditioning circuit and components from moisture when carrying out repair work
- ap4720t0783bb Fuel prefilter with water separator - replacing filter element
- ap8300t8352bad Air conditioning system - function check
- ap8300t8352bas Air conditioning system - function check
- ar1321t0160bas Remove V-belt of refrigeration compressor of air conditioning system, install
- ar8330t1762bas
- ar8330t1762bas Evacuate air conditioning system, leak test
- ar8330t1777bas Fill air conditioning system (liquid)
- ar8330t1777bas
- ar8330t1780bas
- ar8330t1780bas Discharge air conditioning system
- ar8820t2200b Remove and install rear bumper
- as8300z000101a Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant.
- bb0040p036200a Compressor oils (specification 362.0)