ar8350m6400a

Remove/install anti-icing switch for passenger compartment air conditioning

Type ar · topic 83.50 · version 0100 · 2005-09-01

Applies to: MODEL 903.663 Minibus Sprinter Group, with SC1-9 rear air conditioning MODEL 903.663 Minibus Sprinter Group, with SC4-10 rear air conditioning MODEL 904.663 Minibus Sprinter Group, with SC1-9 rear air conditioning MODEL 904.663 Minibus Sprinter Group, with SC4-10 rear air conditioning MODEL 904.663 Minibus Sprinter ECO, with SC1-9 rear air conditioning MODEL 904.663 Minibus Sprinter Tourist, with SC5-10 rear air conditioning MODEL 904.663 Minibus Sprinter Tourist, with SC3-10 rear air condi

Where it sits

Function group 3 Body › 83 Climate control › 83.50 Rear air-conditioning — Series 903 (models 663) · Series 904 (models 663) · Series 905 (models 613)

EinPAS 39 Heating/ventilation/cooling › 39.15 Climate control › 39.15.12 Sensor/switch/wiring harness — Series 903 (models 663) · Series 904 (models 663) · Series 905 (models 613)

AR83.50-M-6400A

Remove/install anti-icing switch for passenger compartment air conditioning

28.2.05

MODEL 903.663
Minibus Sprinter Group,
with SC1-9 rear air conditioning

MODEL 903.663
Minibus Sprinter Group,
with SC4-10 rear air conditioning

MODEL 904.663
Minibus Sprinter Group,
with SC1-9 rear air conditioning

MODEL 904.663
Minibus Sprinter Group,
with SC4-10 rear air conditioning

MODEL 904.663
Minibus Sprinter ECO,
with SC1-9 rear air conditioning

MODEL 904.663
Minibus Sprinter Tourist,
with SC5-10 rear air conditioning

MODEL 904.663
Minibus Sprinter Tourist,
with SC3-10 rear air conditioning

MODEL 904.663
Minibus Sprinter Classic,
with SC2-10 rear air conditioning

MODEL 904.663
Minibus Sprinter Low Floor,
with SC2-10 rear air conditioning

MODEL 904.663
Minibus Sprinter Classic,
with SC3-11 rear air conditioning with auxiliary condenser

MODEL 904.663
Minibus Sprinter Low Floor,
with SC3-11 rear air conditioning with auxiliary condenser

MODEL 905.613
Minibus Sprinter Classic, 6 t,
with SC3-11 rear air conditioning with auxiliary condenser

MODEL 905.613
Minibus Sprinter Low Floor, 6 t,
with SC3-11 rear air conditioning with auxiliary condenser

Remove/install anti-icing switch for passenger compartment air conditioning

M83.50-0037-05

1 Bolt

2 Connector

3 Temperature sensor capillary tubes

X310b4 Anti-icing switch

Remove/install

1

Remove evaporator unit trim

AR83.50-M-5010A

2

Detach both connectors (2) from anti-icing switch (X310b4)

3

Undo bolts (1) and remove anti-icing switch (X310b4).

In doing so, carefully pull the temperature sensor capillary tubes (3) off the evaporator lamellas.

4

Install in the reverse order

Referenced documents