D83.50-1294-08
1 | Cover | 4 | Right air grille | 7 | Nut | ||
2 | Left air grille | 5 | Refrigerant line | ||||
3 | Strut | 6 | Bolts |
D83.50-1295-08
1 | Cover | 8 | Damping material |
| Remove/install | ||
Danger ! | Risk of death caused by falling from vehicle roof. Risk of injury to other persons caused by falling objects during work in roof area. | Model 906.6/7 | |
1 | Remove paneling of condenser unit | ||
2 | Unclip left air grille (2) and right air grille (4) | ||
3 | Unscrew nut (7) of refrigerant line (5) at strut (3) | ||
4 | Remove screws/bolts (6) at left and right at strut (3) | ||
5 | Remove brace (3) | Helper required. | |
6 | Remove screws/bolts (arrows) of paneling (1) | ||
7 | Remove trim panel (1) | | |
Helper required. | |||
Installation: Ensure that paneling (1) is seated correctly. | |||
8 | Remove vapor barrier (8) | Helper required. | |
Installation: Ensure that dampening (8) is seated correctly. | |||
9 | Install in the reverse order |
Referenced documents
- ar8350d5000b Remove/install condenser unit paneling
- as6500z000201a Risk of death caused by falling from vehicle roof. Risk of injury to other persons caused by falling objects during work in roof area.