ar8340s6348e

Remove/install operating unit for climate control

Type ar · topic 83.40 · version 0101 · 2016-01-19

Applies to: Model 447.8 with code HH4 (THERMOTRONIC automatic climate control) Model 447.8 with code HH9 (Air conditioner, automatic heater control) Model 448.8

Where it sits

Function group 3 Body › 83 Climate control › 83.40 Air conditioning (automatic) — Series 447 (models 8**) · Series 448 (models 8**)

EinPAS 39 Heating/ventilation/cooling › 39.15 Climate control › 39.15.33 Operating unit/cable — Series 447 (models 8**) · Series 448 (models 8**)

AR83.40-S-6348E

Remove/install operating unit for climate control

07.12.2015

Model

447.8

with code HH4 (THERMOTRONIC automatic climate control)

Model

447.8

with code HH9 (Air conditioner, automatic heater control)

Model

448.8

Remove/install operating unit for climate control

S83.40-4545-08

1

Screw

2

Locks

S98/1

Front heater/air conditioning operating unit switch

Information on preventing damage to electronic components due to electrostatic discharge

AH54.00-P-0001-01A

Remove/install

1

Remove right trim piece of instrument panel

AR68.10-S-1180E

2

Remove bolts (1)

3

Release locks (2) and remove FRONT heater/air conditioning operating unit switch (S98/1) from trim piece

Installation: FRONT heater/air conditioning operating unit switch (S98/1) must audibly engage at trim piece.

4

Install in the reverse order

Check

5

Check air conditioning system for proper function

Referenced documents